background image

Battery Charging

The battery (BDC70) was not charged at the factory. Charge the battery
fully before using the instrument.

1. Connect the power cable to the charger and plug the charger into the

wall outlet.

2. Mount the battery in the charger by matching the grooves on the bat-

tery with the guides on the charger. When charging starts, the lamp
starts blinking.

3. The lamp lights when charging is finished.

• Be sure to charge the battery within the charging temperature range.

     Charging temperature range: 0 to 40°C

Installing the Battery

1. Slide down the catch on the battery

cover to open.

2. Checking the terminal side on the

battery, insert the battery as shown.

• Do not insert the battery inclined. Doing so may damage the 

instrument or battery terminals.

3. Close the battery cover. A click is heard when the cover is secure.

Upon opening, make sure that all the following are included.

Standard Package Components

For the safe use of the product and prevention of injury to operators and other 
persons as well as prevention of property damage, items which should be 
observed are indicated by an exclamation point within a triangle used with 
WARNING and CAUTION statements in this operator’s manual.
The definitions of the indications are listed below. Be sure you understand 
them before reading the manual’s main text.

Definition of Indication

General

WARNING

Ignoring this indication and making an operation error could 
possibly result in death or serious injury to the operator.

CAUTION

Ignoring this indication and making an operation error could 
possibly result in personal injury or property damage.

This symbol indicates items for which caution (hazard warnings inclusive) is 
urged. Specific details are printed in or near the symbol.

This symbol indicates items which are prohibited. Specific details are printed in 
or near the symbol.

This symbol indicates items which must always be performed. Specific details 
are printed in or near the symbol.

Warning

Do not use the unit in areas exposed to high amounts of dust or ash, in areas 
where there is inadequate ventilation, or near combustible materials. An 
explosion could occur.

Do not perform disassembly or rebuilding. Fire, electric shock, burns, or 
hazardous radiation exposure could result.

Never look at the sun through the telescope. Loss of eyesight could result.

Do not look at reflected sunlight from a prism or other reflecting object through 
the telescope. Loss of eyesight could result.

Direct viewing of the sun during sun observation will cause loss of eyesight. 
Use solar filter (option) for sun observation.

When securing the instrument in the carrying case make sure to set all the 
locks. Failure to do so could result in the instrument falling out while being 
carried, causing injury.

Caution

Do not use the carrying case as a footstool. The case is slippery and unstable 
so a person could slip and fall off it.

Power Supply

Do not place the instrument in a damaged case or in a case with a damaged 
belt. The case or instrument could be dropped and cause injury.

Do not wield or throw the plumb bob. A person could be injured if struck.

Secure handle to main unit. Failure to properly secure the handle could result in 
the unit falling off while being carried, causing injury.

Tighten the adjustment tribrach clamp securely. Failure to properly secure the 
clamp could result in the tribrach falling off while being carried, causing injury.

Warning

Do not disassemble or rebuild the battery or the battery charger, nor expose to 
heavy shocks or vibration. Sparking, fire, electric shock or burns could result.

Do not short circuit. Heat or ignition could result.

Do not place articles such as clothing on the battery charger while charging 
batteries. Sparks could be induced, leading to fire.

Do not use voltage other than the specified power supply voltage. Fire or 
electrical shock could result.

Do not use batteries other than those designated. An explosion could occur, or 
abnormal heat generated, leading to fire.

Do not use damaged power cords, plugs or loose outlets. Fire or electric shock 
could result.

Do not use power cords other than those designated. Fire could result.

Use only the specified battery charger to recharge batteries. Other chargers 
may be of different voltage rating or polarity, causing sparking which could lead 
to fire or burns.

Do not use the battery or charger for any other equipment or purpose. Fire or 
burns caused by ignition could result.

Do not heat or throw batteries or chargers into fire. An explosion could occur, 
resulting in injury.

To prevent shorting of the battery in storage, apply insulating tape or equivalent 
to the terminals. Otherwise shorting could occur resulting in fire or burns.

Do not use the battery or the battery charger if its terminals are wet. Resultant 
poor contact or shorting could lead to fire or burns.

Do not connect or disconnect power supply plugs with wet hands. Electric 
shock could result.

Caution

Do not touch liquid leaking from batteries. Harmful chemicals could cause 
burns or blisters.

Tripod

Bluetooth

 wireless technology/Wireless LAN

Laser Safety

Refer to "LASER SAFETY INFORMATION" in your manual (PDF).

Caution

When mounting the instrument to the tripod, tighten the centering screw 
securely. Failure to tighten the screw properly could result in the instrument 
falling off the tripod, causing injury.

Tighten securely the leg fixing screws of the tripod on which the instrument is 
mounted. Failure to tighten the screws could result in the tripod collapsing, 
causing injury.

Do not carry the tripod with the tripod shoes pointed at other persons. A person 
could be injured if struck by the tripod shoes.

Keep hands and feet away from the tripod shoes when fixing the tripod in the 
ground. A hand or foot stab wound could result.

Tighten the leg fixing screws securely before carrying the tripod. Failure to 
tighten the screws could lead to the tripod legs extending, causing injury.

Warning

Do not use within the vicinity of hospitals. Malfunction of medical equipment 
could result.

Use the instrument at a distance of at least 22 cm from anyone with a cardiac 
pacemaker. Otherwise, the pacemaker may be adversely affected by the 
electromagnetic waves produced and cease to operate as normal.

Do not use onboard aircraft. The aircraft instrumentation may malfunction as a 
result. 

Do not use within the vicinity of automatic doors, fire alarms and other devices 
with automatic controls as the electromagnetic waves produced may adversely 
affect operation resulting in an accident.

Precautions for Safe Operation

Using the Battery

Battery

Charger

(110 to 240 V AC)

To outlet

տ

վ

ր

ց

1

Main unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1

2

Battery (BDC70) . . . . . . . . . . . . . . . . . . . . . . .  1

3

Battery charger (CDC68A) . . . . . . . . . . . . . . .  1

4

Power cable (EDC113A/113B/113C etc.) . . . .  1

5

Lens cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1

6

Lens hood . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1

7

Tool pouch  . . . . . . . . . . . . . . . . . . . . . . . . . . .  1

8

Precision screwdriver . . . . . . . . . . . . . . . . . . .  1

9

Lens brush  . . . . . . . . . . . . . . . . . . . . . . . . . . .  1

10 Hexagonal wrench (1.3 mm/2.5 mm) . . . 1 each
11 Silicon cloth. . . . . . . . . . . . . . . . . . . . . . . . . . .  1
12 Quick Manual (This sheet) . . . . . . . . . . . . . . .  1
13 CD-ROM (Operator's manual)  . . . . . . . . . . . .  1
14 Laser caution sign-board  . . . . . . . . . . . . . . . .  1
15 Carrying case . . . . . . . . . . . . . . . . . . . . . . . . .  1
16 Carrying strap . . . . . . . . . . . . . . . . . . . . . . . . .  1
17 Export restrictions card (Be sure to read) . . . .  1

• A dedicated power cable for the country or the area where the instrument is purchased is attached.
• Instruments with a laser plummet also include a 1.5 mm hexagonal wrench.
• Instruments with a plate level also include an adjusting pin.
• The Operator's manual is an electronic manual provided in a CD-ROM in PDF format. It is recommended that the manual 

files are backed up by transferring to your PC etc. Adobe Acrobat Reader DC is necessary in order to view these documents. 
The latest version of Acrobat Reader DC can be downloaded from the Adobe homepage.

• Some types of USB flash drives may not be recognized on the instrument. Even if the procedure of SD formatting enables 

any USB flash drives to be recognized, TOPCON CORPORATION cannot guarantee safe operation of them.

Battery

Battery

Cover

Charging lamp

Charging: Flashing.
Charging completion: Lighting up.
Charging time: About 5.5 hours

Press the power key to power ON.

Press and hold (about 1 sec) power key to power OFF.

• If you are experiencing problems with the software, depress the reset 

button to reboot the program forcibly. Use a provided hexagonal 
wrench (1.3 mm/1.5 mm) or a tapered rod like a pin to depress down 
the reset button.

• Avoid using any sharp implement like a needle. Malfunction of the 

instrument could result.

• Pressing down the Reset button may result in file and folder data being 

lost.

Reset button

Power ON/OFF

GM-100 series

Quick Manual

1019165-01-A

Power key

GM-100_Quick_E.fm  1 ページ  2017年5月22日 月曜日 午後2時52分

For more information contact Synergy Positioning Systems or

visit the Synergy Positioning Systems website at www.synergypositioning.co.nz

All branches: Phone 0800 867 266 Email: [email protected]