7-4
7 Station Setting
7.3 Setting the Occupied Point Name and the Backsight Point Name
The occupied point name and backsight point name must be set in order to obtain the coordinates of
the scanning object relative to a known point.
Enter the occupied point name, instrument height, backsight point name, and target name. Collimate
the backsight point.
Start the target scanning, and record the backsight point data.
[Example] Use the following settings.
Occupied point name
:
a-1
Instrument height
:
1.5m (Entry range: -999.999m-999.999m)
Backsight point name
:
b-1
Target name
:
t-1
Operating procedure
Operation
Display
1
Press the [F1](STATION MENU) key to select the
station menu.
[F1]
2
Press the [F3](OCC/BS SETTING) key to input the
occupied point name.
[F3]
3
Input the occupied point name [a-1].
Input
occupied
point name
4
Press the [ENT] key.
[ENT]
5
Input instrument height [1.5m].
Input unit is meters (m).
Input
instrument
height
6
Press the [ENT] key.
[ENT]
z
The only target you can use is Topcon target sheets.
z
The target sheet to use differs depending on the scanning distance. Refer to Chapter 4.8.1
“Selecting the Target Sheet”.
SELECT MENU
F1 STATION MENU
F2 SCAN MENU
P1/2
↓
STATION MENU
F1 NEW STATION
F2 SELECT STATION
F3 OCC/BS SETTING
OCC/BS SETTING
INPUT OCC NAME
[ ]
NUME <-
OCC/BS SETTING
INPUT OCC NAME
[a-1 ]
NUME <-
OCC/BS SETTING
INPUT HEIGHT
[ ]
NUME <-
OCC/BS SETTING
INPUT HEIGHT
[1.5 ]
NUME <-
OCC/BS SETTING
INPUT BS NAME
[ ]
NUME <-