GB
27
Automatic defrost
Automatic defrost
is started during the conservation phase and is regulated by the card set-up.
The defrost operation can be manually interrupted by pressing the up button for 4 seconds: the deactivation
of the function will be indicated by the [
ndF
] label flashing on the display.
On the +14 °C / +16 °C and -25°C / -15°C units there is no automatic defrost".
STOPPING
Press this key
for 3 seconds and release it as the display shows the [Sby] to set the appliance to the
stand-by mode.
WARNING
: the main switch
DOES NOT insulate the machine from the electric current.
Set the general cut-out in OFF position.
To isolate the unit from electrical tension disconnect its plug from the outlet.
WORKING IRREGULARITIES
In case of working irregularities, before to call the technical service in zone verify that:
the main switch
is lighting and the current is present;
the regulated temperature is the wished one;
that the door is perfectly closed;
the machine is not near heat sources;
the condenser is clean and the fan works regularly;
an excess of hoarfrost does not cover the evaporating pannel.
In case of negative result, contact the nearest service centre indicating the model and the serial number
shown on the rating placed on the appliance instrument panel.
USAGE INTERRUPTIONS
In case of longer inactivity of the refrigerator and for maintaining it in the best state act as following:
- set the general cut-out in OFF position.
- remove the plug from the socket.
- empty the refrigerator and clean it as described In the chapter "CLEANING".
- let the door open to avold the forming of bad smell.
MALFUNCTIONING
Malfunctioning during operation is often due to banal causes , whitch may nearly all be resolved without the
help of a specialised technician. Consequently, before getting in touch with a service centre, check the
following:
PROBLEM
POSSIBLE CAUSES
The appliance does not start
Check that the plug is properly inserted into the socket.
Check that there is voltage at the socket
The internal temperature is too high
Check the electronic card adjustment
Check for a heat source in the vicinity
Check that the door closes properly