AL-2000 Biometer & Pachymeter
30
4
4..3
3 IIO
OL
L P
Po
ow
we
err C
Ca
allccu
ulla
attiio
on
n
4
4..3
3..5
5 IIO
OL
L p
po
ow
we
err cca
allccu
ulla
attiio
on
n
a
a)) A
Au
utto
om
ma
attiicc p
po
ow
we
err cca
allccu
ulla
attiio
on
n
b
b)) R
Re
eg
giissttrra
attiio
on
n o
off tth
he
e IIO
OL
L m
mo
od
de
ell n
na
am
me
e
cc)) E
En
ntte
erriin
ng
g IIO
OL
L p
po
ow
we
err
When all necessary values have been
entered, IOL power calculations will be per-
formed automatically and results will be dis-
played.
Seven IOL power options (1) and the result-
ing refraction for each (2) will be displayed
for each lens. The IOL power that produces
the refractive result closest to the specified
desired refraction (Desired Ref.) will be high-
lighted.
IIn
n tth
he
e cca
allccu
ulla
attiio
on
n p
prro
occe
essss,, ssm
ma
allll e
errrro
orrss m
ma
ayy o
occccu
urr d
du
ue
e tto
o tth
he
e n
nu
um
mb
be
err o
off
ssiig
gn
niiffiicca
an
ntt ffiig
gu
urre
ess..
IIn
n sso
om
me
e IIO
OL
L ffo
orrm
mu
ulla
ass,, a
an
n iim
ma
ag
giin
na
arryy n
nu
um
mb
be
err m
ma
ayy b
be
e g
ge
en
ne
erra
atte
ed
d d
du
ue
e tto
o
ssq
qu
ua
arre
e rro
oo
ott cca
allccu
ulla
attiio
on
nss a
an
nd
d tth
he
e rre
essu
ulltt m
ma
ayy b
be
e d
diissp
plla
ayye
ed
d a
ass a
an
n E
ER
RR
RO
OR
R..
If you wish to store the IOL model that you
have selected for the patient:
1. Touch the IIm
mp
plla
an
ntte
ed
d IIO
OL
L M
Mo
od
de
el key (1).
2. Touch the highlighted area where IOL
model and manufacturer name are dis-
played (2) to store the IOL model name.
The IOL model name will be stored on the
memory card and may be used for statisti-
cal data analysis (provided that IOL power
is also stored, as described below).
If you wish to store the IOL power of the
lens that you have selected for the patient:
1. Touch the IIO
OL
L P
Po
ow
we
err key (1).
2. Enter the IOL power using the number
keys (2). The acceptable range is 0.01 -
50.00 D.
In the event of an erroneous entry, touch
the D
De
elle
ette
e key (3).
3. Touch the R
Re
ettu
urrn
n key (4) or the IOL key
(1) to register the IOL power.
The IOL power will be stored on the mem-
ory card and may be used for statistical
data analysis (provided that IOL Model is
also stored, as described above).
Summary of Contents for AL-2000
Page 9: ...AL 2000 Biometer Pachymeter...
Page 13: ...AL 2000 Biometer Pachymeter 4...
Page 89: ...AL 2000 Biometer Pachymeter 80 8 8 M Me em mo or ry y C Ca ar rd d...
Page 111: ...AL 2000 Biometer Pachymeter...
Page 118: ...AL 2000 Biometer Pachymeter 109...
Page 119: ......