(8)
Don’t use any electric apparatus before setting the
circuit breaker to the
“ON” position.
2. Electric starting
(1) Remove all the loads out of the output.
(2) Turn the fuel valve to the “ON” position.
(3) Turn the choke lever to the “CLOSE” position.
Don’t close the choke when starting a warm engine
(4) Turn the generator switch to electric starting position.
(5) After starting engine, immediately release generator
switch and generator switch can automatically return to
open position.
(6) Turn the choke lever to “OPEN” position after the engine
is warm.
Turning the gasoline switch to the electric starting position
for more than 5 seconds can damage the starting motor. If
failing to start, release the switch and wait 10 seconds
before operating it again.
If the speed of the starting motor drops fast after a period of
time, it means that the battery should be recharged.
7. STOPPING THE ENGINE
(1) Turn the AC circuit breaker to the
“OFF” position.
(2) Turn the generator switch to the
“OFF” position.
(3) Turn the fuel valve to the
“OFF” position.