ZT-1 User’s Manual – Installation
DOC #18172 Page 21
TRK/PEAK switch setting on the front panel.
•
REV_C terminal outputs the reverse peak (snap-through) tonnage when the front
panel TRK/PEAK switch is set to PEAK.
•
TRK_C terminal always outputs the track tonnage, regardless of the front panel
TRK/PEAK switch.
Triggering – Internal Threshold
The ZT-1 can be triggered by an internal threshold value. When this triggering method is
used, the ZT-1 begins monitoring when the load rises above the level determined by the
front panel’s
Th.H / L
switch. Refer to Figure 10 below to configure the ZT-1 for threshold
triggering.