background image

Installation & Operations Manual

Oven Range

Model RH36, MH36

Manual 1189333 Rev 0 (03/07)
$30..00

Oven Range

IMPORTANT FOR FUTURE REFERENCE

Please complete this information and retain

this manual for the life of the equipment:

Model #: _________________________
Serial #: _________________________
Date Purchased: 

_________________

Manual 2M-1189333 Rev P (12/09)
$30.00

Summary of Contents for MH36

Page 1: ...v 0 03 07 30 00 Oven Range IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment Model _________________________ Serial _________________________ Date Purchased _________________ Manual 2M 1189333 Rev P 12 09 30 00 ...

Page 2: ...extinguisher nozzle directly on the burning grease Direct the nozzle to the outside of the flames to prevent them from spreading Gradually spray closer to the center of the flames to cool and smoother them CAUTION DO NOT move the Oven Range while cooking Pots of liquid could spill causing injury NOTICE Contact your local authorized Service Agency to perform maintenance and repairs A Service Agency...

Page 3: ...n 12 G Marine Oven Range Installation On Curb 12 H Dimension Drawings 13 14 SECTION 3 OPERATION 15 I Component Function and Location 15 II Control Functions and Location 16 III Operation 19 IV Time and Temperature Charts 24 SECTION 4 PARTS LIST 29 Overall Drawing Parts List 30 Convection Oven 34 Deck Oven 36 Vents and Marine Rails 38 SECTION 5 SCHEMATICS 40 Electrical Schematics Wiring 41 83 PROBL...

Page 4: ...III RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 This page intentionally left blank Page I III ...

Page 5: ...anding shelf type stainless steel lined door The oven is insulated on all sides and is equipped with one slide in rack Heating is accomplished with top and bottom formed tubular heating elements which are each controlled by a 3 heat low medium high switch The deck oven has a thermostatic control with a temperature range of 200o F to 550o F 93o C to 287o C The oven will preheat to 450o F 232o C in ...

Page 6: ...located at the front and rear for draining into two wide drawer type receptacles 1 Range Components Descriptions a Griddle for griddling The griddle can be either 24 x24 or 24 x 36 The griddles are controlled by thermostats The 24 x24 griddle has a thermostat control for each of two 12 x24 zones and the 24 x 36 griddle has a thermostat for each of four 9 x24 zones The griddle zones have a temperat...

Page 7: ...griddling The hot plates are thermo statically controlled and have a temperature range of 250o F to 850o F 121o C to 454o C and will preheat to 400o F 204o C in 12 minutes Section 1 Description c Round Hot Plate for stock pot cooking The twin hot plates have a 9 diameter and are controlled by 3 heat low medium high switches Figure 1 3 Hot Plate Figure 1 4 Round Hot Plate ...

Page 8: ...l purpose TOP RH36C1 RH36D1 The all purpose top consists of three 12 x 24 hot plates The all purpose top is not recommended for griddling b Multi Purpose Top RH36C2 RH36D2 The multi purpose top consists of two 12 x 24 hot plates and two 9 round hot plates The multipurpose top is not recommended for gridling Figure 1 5 All Purpose Plate Figure 1 6 Multi Purpose Top ...

Page 9: ... Operations Manual 1189333 Rev 0 03 07 Page 5 c Griddling Top RH36C3 RH36D3 the griddle top consists of one 36 x24 griddle plate d Round Hot Plate Top RH36C4 RH36D4 The round hot plate top consists of six 9 hot plates Figure 1 7 Griddle Top Figure 1 8 Round Hot Plate ...

Page 10: ... e Griddle Round Hot Plate Top RH36C6 RH36D6 The griddle round hot plate top consists of one 24 x24 griddle and two 9 round hot plates f Griddle 12 x24 Hot Plate Top RH36C7 RH36D7 The griddle 12 x 24 hot plate top consists of one 24 x24 griddle and one 12 x24 hot plate Figure 1 9 Griddle Round Hot Plate Figure 1 10 Griddle Hot Plate ...

Page 11: ... kg Model RH36C6 MH36C6 515 lb 234 kg Model RH36C7 MH36C7 545 lb 247 kg Model RH36D1 MH36D1 569 lb 258 kg Model RH36D2 MH36D2 515 lb 234 kg Model RH36D3 MH36D3 588 lb 267 kg Model RH36D4 MH36D4 497 lb 226 kg Model RH36D6 MH36D6 515 lb 234 kg Model RH36D7 MH36D7 545 lb 247 kg Shipping Weight Model RH36C1 MH36C1 610 lb 227 kg Model RH36C2 MH36C2 570 lb 259 kg Model RH36C3 MH36C3 610 lb 277 kg Model ...

Page 12: ... RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 8 Installation Operations Manual 1189333 Rev 0 03 07 NOTES Section 1 Description ...

Page 13: ... made with the delivering carrier 1 Apparent Damage or Loss If damage or loss is apparent it must be noted on the freight bill or express receipt at the time of delivery and must be signed by the carrier s agent driver If this is not done the carrier may refuse the claim The carrier will supply the necessary claim forms 2 Concealed Damage or Loss If damage or loss is NOT apparent until after equip...

Page 14: ...e the metal banding straps and packing materi als and move it to the permanent location If the oven range is packed in two separate cartons and must be moved through a narrow passage follow the Pre Installation instructions located on the outside of the carton If the oven range does not have to be moved through a narrow doorway then simply remove the metal banding straps and packing materials and ...

Page 15: ... terminal block as shown in Figure 2 1 6 Remove all remaining packing materials 7 On Marine Oven Ranges bolt the oven range to the floor deck using the leg brackets D Electrical Connection 1 Remove the right side panel and the front louvered panel located below the control panel if they have not already been removed 2 Remove knockout plate located below terminal block on oven floor as shown in Fig...

Page 16: ...b Convection oven Set thermostat control to 300 F 149 C Push fan switch LOW position Turn oven power switch ON After a few minutes open oven door and check for heat If oven is heating turn all controls to OFF G Marine Oven Range Installation on Curb 1 Installation of Oven Range on metal curb shipped separately a Bolt or weld base flange of metal curb P N33669 to floor of ship See figure 2 2 b Posi...

Page 17: ...13 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 13 Figure 2 4 Section 2 INSTALLATION H Dimension Drawings ...

Page 18: ...14 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 14 Installation Operations Manual 1189333 Rev 0 03 07 Section 2 INSTALLATION Figure 2 5 ...

Page 19: ...EL All Oven operating controls and indicators C RANGE TOP Configured six different ways which consist of griddle round hot plate and or 12 x 24 hot plate D RANGE TOP CONTROL PANEL Contains all operator controls for range top operation E GREASE TROUGHS In front and behind the Range Top cooking surfaces Grease chutes provide drainage into the grease drawers F GREASE DRAWERS Containers for grease dra...

Page 20: ...lso provided with ON OFF position The oven will preheat to 450 F 232 C in 15 minutes 2 Heating Light Amber light signals when oven is coming up to set temperature and heating element is energized 3 Power Switch turns ON or OFF 4 On Light Green light signals when power is on 5 Timer Adjustable from 6 to 120 minutes 6 Fan Switch turns fan to LOW or HIGH speed and turns fan OFF If fan switch is turne...

Page 21: ...en will preheat to 450 F 232 C in 20 minutes 2 Upper and Lower Heating Element Switches are 3 position switches which adjust the heating elements at low medium or high The heating element switches also have an OFF position 3 Heating Light Amber light signals when oven is coming up to set temperature and heating element s is energized 4 Timer Adjustable from 6 to 120 minutes Figure 3 3 Deck Control...

Page 22: ...iddles have independent heat zones each with its own heating element and temperature control The 24 x 24 griddle has two 12 heat zones and the 24 x 36 griddle has four 9 heat zones 2 12 x 24 Hot Plate is controlled by a Temperature Thermostat Control see Figure 3 5 adjustable from 250 F to 850 F 121 C to 455 C The 12 x 24 hot plate will preheat to 400 F 204 C in 12 minutes Adjacent green light rem...

Page 23: ...uneven cooking Keep oven door closed except for necessary checking of food products 6 Flue vent damper should be opened when cooking high moisture content foods Pull the flue vent handle to open the vent damper 7 When timer signal that cooking time has elapsed remove food product and turn power switch temperture control and fna switch to OFF 8 CONVECTION OVEN CLEANING a At the end of the day s ope...

Page 24: ...ock air flow on sides or in back of oven cavity Blocking the air flow can cause uneven cooking Opening the oven door too often will also cause uneven cooking Keep oven door closed except for necessary checking of food products 6 Set timer for desired cook time Refer to the Time and Temperature charts on the following pages for suggested cook times and temperatures 7 Flue vent damper should be open...

Page 25: ...connect switch at the end of each day of operation b Do not leave the griddle in operation without an attendant c Turn thermostat dials down to 200 F 93 C during idle periods It takes only a few minutes to regain operating temperatures d Do not heat the entire griddle for cooking small amounts of food e Various kinds of foods can be cooked at the same time by setting each section of the griddle at...

Page 26: ... CC Clean the griddle surface woth a pumice or griddle stone by rubbing with the grain of the metal while the griddle surface is still warm Wipe griddle clean of residue from the griddle stone b Clening Wipe down sides of griddle and all areas around griddle to keep them free of splashed grease AA Clean all surrounding surfaces of the griddle with warm water and a mild detergent daily BB Rinse and...

Page 27: ...T PLATE CLEANING a Wash range with warm soapy water rinse and wipe dry b Be sure to clean all surfaces around and on the hot plates c Polish with a soft cloth E Round Hot Plate Operation 1 Turn the 3 heat switch to LOW MEDIUM or HIGH Allow the hot plate to preheat for 10 minutes and then place pots or vessels onto hot plate for cooking 2 Green signal light will remian on until 3 heat switch is tur...

Page 28: ...nish Rolls 375 F 400 F 190 C 204 C Medium Medium 20 30 Sweet Rolls 375 F 400 F 190 C 204 C Medium Medium 20 30 Kolacky 375 F 400 F 190 C 204 C Medium Medium 10 15 Tea Biscuits 375 F 400 F 190 C 204 C Medium Medium 20 25 Corn Bread 400 F 425 F 204 C 218 C Medium Medium 25 35 Cup Cakes 400 F 425 F 204 C 218 C Medium Medium 15 20 Layer Cakes 350 F 375 F 176 C 190 C Medium Medium 20 30 Loaf Cakes 350 ...

Page 29: ... F 176 C 185 F 85 C 30 35 Ham Leg 25 pounds 350 F 176 C 185 F 85 C 30 35 Ham Boned 15 pounds 350 F 176 C 185 F 85 C 30 35 Loin 350 F 176 C 185 F 85 C Boston Butt 350 F 176 C 185 F 85 C 45 50 Ham Cured 20 pounds 300 F 149 C 160 F 71 C 15 18 Veal Leg 16 pounds 300 F 149 C 170 F 77 C 22 Leg 25 pounds 300 F 149 C 170 F 77 C 18 20 Shoulder 15 pounds 300 F 149 C 170 F 77 C 25 Shoulder Rolled 15 pounds 3...

Page 30: ...eet Cake 18 x 26 3 3 335 F 168 C 16 18min Corn Bread 18 x 26 3 3 335 F 168 C 25min Bread 1lb Loaves 2 16 340 F 171 C 30min Sugar Cookies 3 dia 18 x 26 3 144 300 F 149 C 15min Brownies 12 x 20 x 2 3 6 350 F 176 C 15min Beef Pot Pies 5 dia 5 dia 3 60 400 F 204 C 30 35min Turkey or Chicken Pot Pies 5 dia 3 60 400 F 176 C 30 35min Stuffed Peppers 2 350 F 176 C 15 20min Toasted Cheese Sandwiches 12 x 2...

Page 31: ...ef Patties 375 F 190 3 4 Open both ends of can Slide out contents of can Cut into 3 8 slices Sausage Patties 350 F 176 C 3 4 Form patties Seperate with waxed paper Refrigerate Sausage Links 350 F 176 C 3 Refrigerate for best results Poatato Patties 375 F 190 3 4 Cook Mash Season Form patties using 1 4 cup measure American Fries Potatoes 375 F 190 3 4 Cook Slice Season French Toast 400 F 204 C 4 5 ...

Page 32: ...28 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 28 Installation Operations Manual 1189333 Rev 0 03 07 NOTES Section 3 OPERATION ...

Page 33: ...S MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 29 SECTION 4 PARTS LIST Order parts by calling your authorized Toastmaster Parts Distributor who has a complete inventory of parts for all Toastmaster equipment ...

Page 34: ...30 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 30 Installation Operations Manual 1189333 Rev 0 03 07 Section 4 PARTS LIST ...

Page 35: ...EATING UNIT 208V ECO 2600W 2N 1132B8703 SOLID RND HEATING UNIT 240V ECO 2600W 2N 34127 SOLID RND HEATING UNIT 480V ECO 2600W 22 1 3 N2 7610114 TWIN PLATE PANEL 23 1 3 N2 1132B8901 RETAINER BAR MOUNTING BRACKET 24 2 6 N2 34285 RETAINING CLIP 25 1 3 N2 30999 BOTTOM PLATE Item No Qty Part No Description 26 1 N2 20G1A32 36X24 GRIDDLE PLATE CMPLT 208V N2 20G1A302 36X24 GRIDDLE PLATE CMPLT 240V N2 20G1A...

Page 36: ...32692 PLATE LATCH 66 2 2A 34081 SPACER STEPPED MARINE LATCH 67 1 N2 32572 ASSEMBLY HANDLE DOOR 68 2 2A 3103164 SPACER DOOR DRAWER HANDLE 69 4 2V 2000320 HANDLE SCREWS 10 32 X 3 12 70 2 2V 3000058 BLACK HANDLE PLUG NI 2M 31795 DECAL RH36C3 RH36D3 CONTROL PANEL 2M 31796 DECAL RH36C4 RH36D4 CONTROL PANEL 2M 31794 DECAL RH36C2 C6 RH36D2 D6 CONTROL PANEL 2M 31793 DECAL RH36C1 C7 RH36D1 D7 CONTROL PANEL...

Page 37: ...33 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 38 Installation Operations Manual 1189333 Rev 0 03 07 NOTES Section 4 PARTS LIST ...

Page 38: ...34 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Section 4 PARTS LIST 33 34 35 36 IL2012 ...

Page 39: ... 15 1 2A 30359 AXLE 16 2 2C 3102937 RETAINER RING 17 1 2E 3003770 MICRO SWITCH 18 1 N2 32762 MOTOR DUCT 19 1 2I 34404 MOTOR DUCT SEAL 20 1 2E 30519 HIGH LIMIT SENSOR 21 AR 2E 32941 SWITCH 3HT 22 AR 2R 33365 KNOB SWITCH 23 AR 2E 33413 SIGNAL LIGHT GREEN 250V 2E 33414 SIGNAL LIGHT AMBER 250V 2E 33415 SIGNAL LIGHT WHITE 250V 2E 33417 SIGNAL LIGHT GREEN 480V 2E 33418 SIGNAL LIGHT AMBER 480V 2E 33419 S...

Page 40: ...36 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 34 Installation Operations Manual 1189333 Rev 0 03 07 Section 4 PARTS LIST ...

Page 41: ...5 1 N2 3024A3217 GUARD THERMOSTAT BULB 6 1 2P 30368 SPRING DOOR 7 1 2C 43685 EYEBOLT 8 1 N2 30369 CABLE ASSEMBLY 9 1 2E 30905 TERMINAL BLOCK 3POLE 10 1 2ER 7007809 SHEAVE 3 16 DIA CABLE PULLEY 11 1 2A 30359 AXLE 12 2 2C 3102937 RETAINER RING 13 2 6 2E 32941 SWITCH 3HT 14 2 6 2R 33365 KNOB SWITCH 15 AR 2E 33413 SIGNAL LIGHT GREEN 250V 2E 33414 SIGNAL LIGHT AMBER 250V 2E 33417 SIGNAL LIGHT GREEN 480...

Page 42: ...38 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 36 Installation Operations Manual 1189333 Rev 0 03 07 Section 4 PARTS LIST ...

Page 43: ...A2C82 RAIL HAND 7 1 N2 7001408 BRACKET RAIL LIT MARINE 8 1 N2 7001409 BRACKET RAIL RT MARINE 9 2 N2 7004267 POST SEEA RACKS 10 1 2V 7000071 ROD VENT RA 11 1 2R 2100053 KNOB VENT T PULL OPEN 12 1 N2 7610705 WELDMENT FLAP VENT 13 1 N2 30412 WELDMENT FLUE OVEN SECTION 14 1 N2 30415 WELDMENT FLUE TOP SECTION 15 1 N2 32792 WELDMENT FLUE TOP SECTION 16 1 2A 2002305 VENT KNOB PIN 17 1 2C 18A12 COTTER PIN...

Page 44: ...40 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 39 SECTION 5 SCHEMATICS ...

Page 45: ...41 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 40 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36D1 SCHEMATIC 208 240V ...

Page 46: ...42 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 41 Section 5 SCHEMATICS RH36D1 WIRING DIAGRAM 208 240V ...

Page 47: ...43 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 42 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36D2 SCHEMATIC 208 240V ...

Page 48: ...44 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 43 Section 5 SCHEMATICS RH36D2 WIRING DIAGRAM 208 240V ...

Page 49: ...45 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 44 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36D3 SCHEMATIC 208 240V ...

Page 50: ...46 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 45 Section 5 SCHEMATICS RH36D3 WIRING DIAGRAM 208 240V ...

Page 51: ...47 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 46 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36D4 SCHEMATIC 208 240V ...

Page 52: ...48 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 47 Section 5 SCHEMATICS RH36D4 WIRING DIAGRAM 208 240V ...

Page 53: ...49 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 48 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36D6 SCHEMATIC 208 240V ...

Page 54: ...50 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 49 Section 5 SCHEMATICS RH36D6 WIRING DIAGRAM 208 240V ...

Page 55: ...51 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 50 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36D7 SCHEMATIC 208 240V ...

Page 56: ...52 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 51 Section 5 SCHEMATICS RH36D7 WIRING DIAGRAM 208 240V ...

Page 57: ...53 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 52 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C1 SCHEMATIC 208 240V ...

Page 58: ...54 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 53 Section 5 SCHEMATICS RH36C1 WIRING DIAGRAM 208 240V ...

Page 59: ...55 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 54 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH3621 SCHEMATIC 480V ...

Page 60: ...56 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 55 Section 5 SCHEMATICS RH36C2 WIRING DIAGRAM 480V ...

Page 61: ...57 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 56 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS ...

Page 62: ...58 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 57 Section 5 SCHEMATICS ...

Page 63: ...59 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 58 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C2 SCHEMATIC 208 240V ...

Page 64: ...60 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 59 Section 5 SCHEMATICS RH36C2 WIRING DIAGRAM 208 240V ...

Page 65: ...61 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 60 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C2 SCHEMATIC 480V ...

Page 66: ...62 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 61 Section 5 SCHEMATICS RH36C2 WIRING DIAGRAM 480V ...

Page 67: ...63 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 62 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C3 SCHEMATIC 208 240V ...

Page 68: ...64 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 63 Section 5 SCHEMATICS RH36C3 WIRING DIAGRAM 208 240V ...

Page 69: ...65 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 64 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C3 SCHEMATIC 480V ...

Page 70: ...66 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 65 Section 5 SCHEMATICS RH36C3 WIRING DIAGRAM 480V ...

Page 71: ...67 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 66 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C4 SCHEMATIC 208 240V ...

Page 72: ...68 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 67 Section 5 SCHEMATICS RH36C4 WIRING DIAGRAM 208 240V ...

Page 73: ...69 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 68 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C4 SCHEMATIC 480V ...

Page 74: ...70 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 69 Section 5 SCHEMATICS RH36C4 WIRING DIAGRAM 480V ...

Page 75: ...71 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 70 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C6 SCHEMATIC 208 240V ...

Page 76: ...72 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 71 Section 5 SCHEMATICS RH36C6 WIRING DIAGRAM 208 240V ...

Page 77: ...73 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 72 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C6 SCHEMATIC 480V ...

Page 78: ...74 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 73 Section 5 SCHEMATICS RH36C6 WIRING DIAGRAM 480V ...

Page 79: ...75 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 74 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C7 SCHEMATIC 208 240V ...

Page 80: ...76 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 75 Section 5 SCHEMATICS RH36C7 WIRING DIAGRAM 208 240V ...

Page 81: ...77 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 76 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C7 SCHEMATIC 480V ...

Page 82: ...78 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 77 Section 5 SCHEMATICS RH36C7 WIRING DIAGRAM 480V ...

Page 83: ...79 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 78 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS RH36C7W SCHEMATIC 208 240V ...

Page 84: ...80 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 79 Section 5 SCHEMATICS RH36C7W WIRING DIAGRAM 208 240V ...

Page 85: ...81 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 80 Installation Operations Manual 1189333 Rev 0 03 07 Section 5 SCHEMATICS ...

Page 86: ...82 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Installation Operations Manual 1189333 Rev 0 03 07 Page 81 Section 5 SCHEMATICS ...

Page 87: ...83 RH36 MH36 INSTALLATION OPERATIONS MANUAL 2M 1189333 Page 82 Installation Operations Manual 1189333 Rev 0 03 07 This page intentionally left blank ...

Page 88: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 800 807 9054 314 781 2777 Parts Service 800 807 9054 www star mfg com ...

Reviews: