background image

VS-900 Security Intercom Systems

Application Note

Using a Speaker and 25V Line-Matching
Transformer as a VS-900 Sub-Station

Summary

You can build a simple VS-900 sub-station using readily available components.

Details

The configuration shown below supports half-duplex conversation, scan monitoring,
and paging. With the addition of a call switch, the speaker can initiate a call-in to a
pre-programmed master station. Note: Connect only one speaker assembly to each
VS-900 port.

Diagram

10 

µ

f 50 V

VS-900MF

VS-900RS

RS1 ~ RS4

A

B

C

Line 1 ~ 16
(CN1 ~ CN4)

1 k

 (1/4 W)

Call Switch

(Optional)

25 V 1 W

+

TOA Electronics, Inc.

601 Gateway Blvd., Ste. 300

So. San Francisco, CA 94080

1-650-588-2538 / 1-800-733-4750 V1, 

 All Rights Reserved, 2002