Chapter 8: INSTALLATION AND SETTING PROCEDURES (HARDWARE)
2. VX-2000, VX-200Xr, VX-200XI, AND EV-200
8-17
OUTSIDE
• Set to this position when using the external power supply.
• Permits the control input to be insulated.
INSIDE (factory-preset position)
• Set to this position when using the internal power supply.
SJP1203 (Cut to insulate the control output.)
SW1201 (Used to insulate the control input.)
VX-2000 Rear panel
2.3. Insulating the VX-2000 Control I/O
Because the VX-2000's control inputs and outputs employ photocouplers, they can be insulated by performing
the following settings to be powered from external equipment.
Step 1.
remove the top panel.
refer to
"2.1. removing the VX-2000's Top and front Panels."
Step 2.
Perform the setting.
2-1.
Insulating the control input
Shift the SW1201 switch to the OuTSIDE position. This switch is factory-preset to the INSIDE position.
2-2.
Insulating the control output
cut SJP1203.
Step 3.
replace the top panel.
Summary of Contents for VP-2241
Page 12: ...Chapter 1 Note...
Page 17: ...Chapter 2 ProduCt desCriPtioNs...
Page 41: ...3 1 Chapter 3 system oPeratioN outliNe...
Page 56: ...Chapter 4 FuNCtioNs...
Page 73: ...Chapter 5 oPeratioN...
Page 112: ...Chapter 6 FloWCHart From system setuP to oPeratioN...
Page 116: ...Chapter 7 PC soFtWare oFFliNe settiNGs...
Page 179: ...Chapter 8 iNstallatioN aNd settiNG ProCedures HardWare...
Page 223: ...Chapter 9 CoNNeCtioNs...
Page 266: ...Chapter 10 PC oNliNe CHeCKs aNd adJustmeNts...
Page 282: ...Chapter 11 otHer PC soFtWare FuNCtioNs...
Page 292: ...Chapter 12 aPPeNdiX...
Page 298: ...Chapter 13 sPeCiFiCatioNs...
Page 328: ...url http www toa jp 201409...