Step 5. Remove the CF card from the card slot.
Step 6. Insert the CF card into the PC's card slot and start the SX-2000 Setting Software.
Confirm the log data using the SX-2000 Setting Software.
For details, see the separate Setting Software Instructions, "Utility."
Step 7. Insert the CF card with the saved settings data into the SX-2000SM's CF card slot.
Inserting the CF card causes the buzzer to sound.
Setting DIP switch 2 to OFF in Step 8 stops the buzzer.
Step 8. Set DIP switch 2 to OFF.
The CF card can be inserted.
Note
When changing the setting data, be sure to press the Reset key to
restart the SX-2000 system after turning off DIP switch 2.
Reactivating the system stops broadcasts currently in progress.
Step 9. Replace the protective cover.
10. FAILURE INDICATIONS
10.1. SX-2000SM
GENERAL indicator
SX LINK indicator
CPU indicator
SX-2000SM
or
General indicator lights or flashes yellow.
Failure Indication
Description
SX Link indicator flashes yellow.
CPU indicator lights yellow.
A failure is detected in the system.
Both of the rear panel-mounted SX link
terminals A and B are unconnected.
A failure is detected in the SX-2000SM.
ON
1 2 3 4 5 6 7 8