background image

2

1. SAFETY PRECAUTIONS

• Before installation or use, be sure to carefully read all the instructions in this section for correct 

and safe operation.

• Be  sure  to  follow  all  the  precautionary  instructions  in  this  section,  which  contain  important 

warnings and/or cautions regarding safety.

• After reading, keep this manual handy for future reference.

Indicates a potentially hazardous situation which, if mishandled, could 

result in death or serious personal injury.

WARNING

Indicates a potentially hazardous situation which, if mishandled, could 

result in moderate or minor personal injury, and/or property damage.

CAUTION

WARNING

When the Unit is in Use
• Use  TOA’s  IR-310BC  Battery  Charger  when 

recharging.

 The infrared wireless microphone can be 

powered by optionally available nickel metal 

hydride (NiMH) batteries. The use of any 

other than the specified charger could result 

in  fire,  personal  injury  or  environmental 

contamination due to battery rupture or 

leakage. 

• Stop  charging  if  the  batteries  are  not  fully 

charged within 3 hours. Failure to do so may 

cause the batteries to fire, explode, leak, or 

heat.

• Never  short-circuit  the  charging  terminals 

on the bottom of the microphone with metal 

objects.

  Doing so could result in electric shocks or 

burns.

• To  prevent  the  electromagnetic  wave  from 

badly  influencing  medical  equipment,  make 

sure to switch off the unit’s power when 

placing  it  in  close  proximity  to  the  medical 

equipment.

When the Unit is in Use
• When  the  unit  is  not  in  use  for  14  days  or 

more, be sure to take the batteries out of 

the unit because battery leakage may cause 

a  fire,  personal  injury,  or  environmental 

contamination.

• Make sure to observe the following handling 

precautions  so  that  a  fire  or  personal  injury 

does not result from leakage or explosion of 

the battery. 
· Be  sure  to  use  only  the  IR-200BT 

Rechargeable Battery designed for use with 

the infrared wireless microphone.

· Do not short, disassemble, heat nor put the 

battery into a fire.

· Do not solder a battery directly.

· Note correct polarity (positive and negative 

orientation) when inserting a battery in the 

unit.

· Avoid  locations  exposed  to  the  direct 

sunlight, high temperature and high humidity 

when storing batteries.

• When  you  discard  batteries,  please  contact 

the local dealer from whom you bought. 

CAUTION

Summary of Contents for IT-310M

Page 1: ...ING PRECAUTIONS 4 5 Nomenclature AND FUNCTIONS 4 6 BATTERY INSERTION 5 7 WHEN OPERATING ON RECHARGEABLE BATTERIES 6 7 1 How to Charge 6 7 2 Charging Timing 7 8 OPERATION 7 9 INFRARED WIRELESS MICROPHONE USAGE TIPS 8 9 1 When Holding the Microphone By Hand or Hanging It Around the Neck 8 9 2 Setting the Microphone Sensitivity Selector Switch 8 9 3 Microphone to Mouth Distance 9 9 4 When Using the C...

Page 2: ... do so may cause the batteries to fire explode leak or heat Never short circuit the charging terminals on the bottom of the microphone with metal objects Doing so could result in electric shocks or burns To prevent the electromagnetic wave from badly influencing medical equipment make sure to switch off the unit s power when placing it in close proximity to the medical equipment When the Unit is i...

Page 3: ...pt any interference received including interference that may cause undesired operation Any modifications made to this device that are not approved by TOA Corporation may void the authority granted the user by the FCC to operate this equipment FCC Compliance Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules Thes...

Page 4: ...red microphone in high temperature locations such as in a car parked with its doors closed in summer or in highly humid locations as this could lead to microphone failure Avoid using the infrared microphone in locations that can be splashed with perspiration or seawater as this could lead to microphone failures When cleaning the infrared microphone be sure to turn the power switch to OFF Wipe with...

Page 5: ...0M to the front of your clothes for hands free use 8 Battery cover Contains the battery compartment Be sure to open and close the cover correctly Refer to p 5 BATTERY INSERTION 9 Neck strap Used to hang the infrared wireless microphone around the neck Refer to p 8 INFRARED WIRELESS MICROPHONE USAGE TIPS 10 Channel selector switch Set the selector switch to the desired channel A or B Refer to p 10 ...

Page 6: ...rged if the power is ON Step 2 Place an IR 200BT rechargeable battery in the IR 310M Refer to p 5 BATTERY INSERTION Step 3 Fully insert the IR 310M into the microphone receptacle of the IR 310BC Battery Charger The IR 310BC s charging indicator lights red and charging begins Charging is completed in about 3 hours and the IR 310BC s full charge indicator lights green Notes Insert the IR 310M so tha...

Page 7: ...s the battery indicator s color gradually changes from green to red If the indicator lights red during use charge the IR 310M immediately since the microphone will be disabled several minutes after the indicator has lit red Guidelines on the rechargeable battery operation time Continuous usage time About 8 hours Notes When using the IR 200BT rechargeable battery for the first time or when using it...

Page 8: ...nfrared emitter will disable light transmission IR 820SP Infrared Wireless Speaker IR 801AF Audio Interface Unit Speaker Revolving light IR 802T Infrared Wireless Tuner IR 310M Infrared Wireless Microphone Audio output Control output Amplifier ON OF F Example of Function button usage Push the Function button while speaking 9 2 Setting the Microphone Sensitivity Selector Switch The microphone sensi...

Page 9: ...environment of use set the sensitivity to L position Notes Be sure to switch the unit s power OFF before setting Avoid bringing the microphone too close to your mouth or speaking too loud into the microphone Otherwise reproduced voices may become muddy or cracking The sensitivity is factory set to H position Step 1 Check that the power is switched OFF then remove the battery cover Refer to p 5 BAT...

Page 10: ... wireless microphones set to the same channel Set channels correctly Refer to CHANNEL SETTING above Infrared wireless microphone used too close to the tuner Keep the infrared microphone at least 50 cm 20 away from the infrared tuner 10 CHANNEL SETTING Note Make sure that the IR 310M s channel is set to the desired channel A or B Step 1 Switch the unit s power OFF Refer to p 5 BATTERY INSERTION Not...

Page 11: ...Maximum Input Sound Pressure 120 dB SPL Input Sensitivity Adjustment Adjustment range 2 levels High Low Frequency Response 100 Hz 12 kHz Preemphasis 300 µs Input External microphone input ø3 5 monaural mini jack phantom powered Switch Power switch Channel selector switch Microphone sensitivity selector switch Function button Indicator Power battery indicator Battery Operation Time Approx 8 hours w...

Page 12: ...URL http www toa jp 133 07 325 60 ...

Reviews: