background image

Step 1.

Using the volume control, adjust the volume to an
appropriate level that does not generate feedback when
holding down the talk switch.

Howling is more likely to occur when using the
megaphone indoors or in other reverberant places.
Particularly when the batteries are new, it may be
impossible to adjust the volume to maximum without
causing howling. In such cases, set the volume to about
mid-level.

Step 2.

Speak into the mouthpiece at a distance of about 1 cm.

Notes

• Speaking too far from the mouthpiece or in too soft

voice may result in insufficient volume.

• Moisture droplets collecting in the hole on the

mouthpiece may cause noticeably insufficient volume.
Wipe the droplets away with a cloth or other material
and allow the area to dry sufficiently before resuming
use. 

[For ER-1215S]

When using the siren, pressing the talk switch will cause the
siren to stop sounding so that the voice announcement can be
heard. Releasing the talk switch allows the siren to resume. 

7. HOW TO USE

Polarity diagram

Tab

Close

Slot

Battery case

Mouth

Open

1

3

5

6

2

7
8

4

5. NOMENCLATURE AND FUNCTIONS

1. Speaker (outer horn)

2. Shoulder strap

Use this strap to hang the
unit from the shoulder for
transport or use.
(Length: approx. 50 cm)

3. Mouth

The battery compartment is
built inside. Turn the cover
counterclockwise to open it
and clockwise to close it.

4. Mouthpiece

Speak into the mouthpiece
at a distance of about 1 cm.
Anti-bacteria treated, the
mouthpiece helps make
such close contact during
use hygienic and safe.

5. Talk switch

Press to talk (power turns
ON). Release to turn the
power OFF.

6. Signal tone switch 

(ER-1215S only)
A siren tone sounds when
this switch is pressed, and
stops when pressed again.

Note

Output volume is fixed, and
cannot be adjusted with the
volume control.

7. Volume control

Rotate right to increase
output volume.

8. Handle

The handle with anti-bacteria
treatment improve hygiene
and safety during use.

Volume high

Step 1.

Rotate the mouth counterclockwise to remove it.

Note

If the megaphone is at all wet, be sure to dry it
thoroughly before opening it to replace the batteries. 

Step 2.

Insert six C batteries referring to the polarity diagram on
the inside of the battery compartment.

Step 3.

Insert the tab on the inside of the battery cover into the
slot in the battery compartment as shown and turn the
battery cover clockwise until tight.

6. REPLACING THE BATTERIES

Printed in Indonesia

533-03-020-40

CAUTION

• Before pressing the talk switch, fully turn down the

volume.

• Point the megaphone toward the ground when conducting

operational tests.