Step 1.
Using the volume control, adjust the volume to an
appropriate level that does not generate feedback when
holding down the talk switch.
Howling is more likely to occur when using the
megaphone indoors or in other reverberant places.
Particularly when the batteries are new, it may be
impossible to adjust the volume to maximum without
causing howling. In such cases, set the volume to about
mid-level.
Step 2.
Speak into the mouthpiece at a distance of about 1 cm.
Notes
• Speaking too far from the mouthpiece or in too soft
voice may result in insufficient volume.
• Moisture droplets collecting in the hole on the
mouthpiece may cause noticeably insufficient volume.
Wipe the droplets away with a cloth or other material
and allow the area to dry sufficiently before resuming
use.
[For ER-1215S]
When using the siren, pressing the talk switch will cause the
siren to stop sounding so that the voice announcement can be
heard. Releasing the talk switch allows the siren to resume.
7. HOW TO USE
Polarity diagram
Tab
Close
Slot
Battery case
Mouth
Open
1
3
5
6
2
7
8
4
5. NOMENCLATURE AND FUNCTIONS
1. Speaker (outer horn)
2. Shoulder strap
Use this strap to hang the
unit from the shoulder for
transport or use.
(Length: approx. 50 cm)
3. Mouth
The battery compartment is
built inside. Turn the cover
counterclockwise to open it
and clockwise to close it.
4. Mouthpiece
Speak into the mouthpiece
at a distance of about 1 cm.
Anti-bacteria treated, the
mouthpiece helps make
such close contact during
use hygienic and safe.
5. Talk switch
Press to talk (power turns
ON). Release to turn the
power OFF.
6. Signal tone switch
(ER-1215S only)
A siren tone sounds when
this switch is pressed, and
stops when pressed again.
Note
Output volume is fixed, and
cannot be adjusted with the
volume control.
7. Volume control
Rotate right to increase
output volume.
8. Handle
The handle with anti-bacteria
treatment improve hygiene
and safety during use.
Volume high
Step 1.
Rotate the mouth counterclockwise to remove it.
Note
If the megaphone is at all wet, be sure to dry it
thoroughly before opening it to replace the batteries.
Step 2.
Insert six C batteries referring to the polarity diagram on
the inside of the battery compartment.
Step 3.
Insert the tab on the inside of the battery cover into the
slot in the battery compartment as shown and turn the
battery cover clockwise until tight.
6. REPLACING THE BATTERIES
Printed in Indonesia
533-03-020-40
CAUTION
• Before pressing the talk switch, fully turn down the
volume.
• Point the megaphone toward the ground when conducting
operational tests.