![Toa DP-SP3 Operating Instructions Manual Download Page 21](http://html1.mh-extra.com/html/toa/dp-sp3/dp-sp3_operating-instructions-manual_1122410021.webp)
21
Slotted screwdriver*
Tightens
Loosens
Terminal screw
Removable terminal plug
(accessory)
Recommended type of screwdriver with the following blade width:
For 5P terminal plug: About 2.5mm (0.1”) wide blade
For 3P terminal plug: About 3.5mm (0.14”) wide blade
*
Bit shape 2.5 mm or 3.5 mm
(0.1”) (0.14”)
1
1
14.2. Removable Terminal Plug Connection
Notes
• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened
and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.
• When connecting 2 cables or a shielded cable to a single terminal, use a ferrule terminal with an insulation
sleeve to crimp the cables because such cable conductors could become loose.
Recommended ferrule terminals for signal cables
(made by Phoenix Contact)
Recommended ferrule terminals for power supply
cables (made by Phoenix Contact)
Crimping tool: CRIMPFOX UD6-4 (made by Phoenix Contact)
Cable sheath to trim
Model Number
a
l
1
l
2
AI 0,34-8 TQ
AI 0,5-8 WH
2 (0.08)
Unit: mm (in)
2.5 (0.1)
12.5 (0.49)
14 (0.55)
8 (0.31)
8 (0.31)
b
0.8 (0.03)
1.1 (0.04)
Model Number
a
1
l
1
l
2
AI 1,5-8 BK
AI-TWIN 2 x 1,5-8 BK
6.6 (0.26)
a
2
3.6 (0.14)
14 (0.55)
16 (0.63)
2.3 (0.09)
8 (0.31)
8 (0.31)
a
3.4 (0.31)
Unit: mm (in)
b
1.8 (0.07)
Insulation sleeve
Contact section
Insulation sleeve
Contact section
a
l
2
a
1
a
2
l
1
l
2
l
1
b
b
Solid cable and stranded cable
Shielded cable
7 mm*
(0.28'')
(0.28'')
(0.79'')
7 mm*
20 mm
* Expose 8 mm (0.31’’) or more when
using the above ferrule terminal, and cut
off an extra conductor protruding from
the sleeve.
Wiring procedures
Step 1. Wiring the supplied removable terminal
plug.
1-1. Loosen the terminal screws to insert
the wire.
1-2. Tighten the terminal screws.
Ensure that the wire does not break
free when pulled. If the wire does pull
free, repeat the connection procedure
from the start.
Step 2. Insert the wired terminal plug into the
corresponding terminal block in the
unit’s rear panel.
Note
Do not reverse Steps 1 and 2 above. Force is
applied to the connected receptacle pins while
tightening the terminal screw and they may be
damaged, resulting in bad connector contact.