3.4 PROGRAMMABLE FUNCTION SETTINGS
F3
F4
F5
F6
F7
F8
F9
FA
F5-1
F5-2
F5-3
F5-4
F5-5
F5-6
F5-7
F5-8
F5-9
F6-0
F6-1
F6-2
F6-3
F6-4
F6-5
F7-0
F7-1
F8-1
F8-2
F8-3
F8-4
F9-1
F9-2
F9-3
F9-4
FA-0
FA-1
FA-2
FA-3
LED Display
Definition Function
Value
Description
The reactions of the
photocells/ safety
edge/ loop detector
when they detecting
obstacles
Motor Speed
Motor Over Current
Setting
Pedestrian Mode
Pre-flashing
Deceleration point
programming of total
travel distance
Deceleration Speed
Auto - Reverse when
object impacted
3 seconds
6 seconds
9 seconds
12 seconds
15 seconds
18 seconds
The flashing light blinks when
the gate starts to move.
The flashing light blinks 3
seconds before the gate
starts to move.
75%
80%
85%
90%
100% System learning speed
80% System learning speed
50% System learning speed
30% System learning speed
No Auto - reverse
1 second
3 seconds
Reverse to the end
Please refer to page 9,
F3 settings
F3-1
F3-2
F3-3
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
Light
Heavy
F1
F2
Options of Gate
Opening direction
Automatic Closing
F1-0
F1-1
F2-0
F2-1
F2-2
F2-3
F2-4
F2-5
F2-6
F2-7
F2-8
Clockwise Opening
Counterclockwise Opening
No automatic closing
5 seconds
15 seconds
30 seconds
45 seconds
60 seconds
80 seconds
120 seconds
180 seconds
1. The function can adjust the dir
ection of gate opening.
2. The factory setting is "F1-1".
1. This function can cause the gate
to close automatically after the
paused time.
2. The factory setting is "F2-0”:
No automatic closing .
1. The factory setting is “F3-3”.
1. The function can adjust the
running force of motor to be
compatible with the gate weight.
2. The factory setting is "F5-4".
3. The motor force value:
F5-1: 2A F5-6: 7A
F5-2: 3A F5-7: 8A
F5-3: 4A F5-8: 10A
F5-4: 5A F5-9: 13A
F5-5: 6A
4. As over current setting
1. The function can adjust the time
of opening partially.
2. The factory setting is "F6-1".
3. Press button B on the remote to
operate the pedestrian mode.
1. The factory setting is "F7-0".
1. The factory setting is “F8-4”.
1. The factory setting is “F9-4”.
1. The factory setting is “FA-3”.
F1-0
F1-1
Clockwise
Opening
Gate Closed
Gate Closed
Counterclockwise
Opening
Speed 1
50%
70%
85%
100%
Speed 2
50%
60%
70%
80%
1. The function can adjust the running
speed of motor.
2. Speed 1: Motor full speed;
Speed 2: Speed during learning mode (of full speed)
3. The factory setting is “F4-4.”
F4-1
F4-2
F4-3
F4-4