TMK sp.j. Września
ul. Szosa Witkowska 105
tel./fax +48 61 437 97 60
www.tmk.com.pl
Blower controller
with digital temperature display
SW 100W
Installation and Operation
Manual
Applications
SW 100W is a controller designed for automatically switching on/off the blower operating with a CH boiler.
The controller maintains the temperature level set in the scale, and ensures the combustion of gases
accumulating inside the boiler. After the boiler is extinguished, the blower becomes deactivated, which
reduces energy consumption. The controller is equipped with an additional protective device (a thermal cut-
out) to lower the risk of boiler overheating. The digital display shows the temperature of water in the system.
SW 100W is a very simple-to-operate model.
Technical specifications
- Supply voltage
230V / 50Hz
- Maximum load capacity
100VA
- Range of boiler temperature adjustment
35-
90°C
- Temperature measurement range
20-
99°C
- Blower hysteresis
2°C
- Duration of blow-through
0-18 s
- Intervals between blow-through operations
6 min