WWW.TMGINDUSTRIAL.COM
P13/27
Toll Free:1-877-761-2819
Battery Disconnection
Once operating, the compressor will continue
to run whether the battery is connected or not.
It can be disconnected while the compressor
is running. The battery should be
disconnected from the engine when the
compressor is not going to be used for a long
period of time. Always disconnect cables in
this reverse sequence to the above
connection sequence .
1. First, disconnect the
black
(-) cable
from the battery negative (-) terminal.
2. Next, disconnect the
red
cable from
the battery positive (+) terminal.
3. Disconnect the
black
(-) cable from the
grounding connection.
4. Disconnect the
red
(+) cable from
the starter solenoid terminal.
Install Spark Arrestor (if Required)
Equip engine with spark arrestor if machine will
be used near any ignitable forest, brush, or
grassy land. (See engine Owner’s Manual
provided to determine if the engine is already
equipped.) Make sure you comply with
applicable local, state, and federal codes.