172-65591A-01 (P46UC-Y) 19 Jan 2021
7
Disassembly/Reassembly
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the product
has cooled to room temperature. Disassembling or removing the
product when it is hot or under pressure may lead to discharge of fluids,
causing burns, other injuries or damage.
CAUTION
The Disassembly/Reassembly procedures shown below are only for the P46UC-Y (trap
unit). Please follow the instruction manual provided by the manufacturer when
disassembling / assembling the connector unit itself.
Use the following procedures to remove the product and components. Use the same
procedures in reverse to reassemble.
(Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.)
Detaching / Reattaching the Trap Unit
Part
During Disassembly
During Reassembly
Connector Bolts Remove with a socket wrench
Consult the table of tightening torques
and tighten to the proper torque
Trap Unit
Remove the trap unit
Follow the special instructions below
(Fig. A)
Inner/Outer
Connector
Gaskets
Remove with a scraper and
clean the connector flange with a
soft tool
Replace with new gaskets; to facilitate
assembly and prevent loosening of the
gaskets, apply a small amount of
adhesive at 120º intervals around the
outer edge of the gaskets
Attaching the Trap Unit to the Connector Unit (Fig. A)
1. If attaching a new trap unit, be sure to remove the protective
cap from the connector flange. Be careful not to drop the
gaskets when removing the cap.
2. Grasp the end of the trap unit and align its gasket housing with
the indentation on the connector unit. Be sure to have the
nameplate facing upwards.
3. Once aligned, insert and finger tighten the connector bolts.
Verify that the trap unit is within the allowable inclination.
Figure A
Disassembly / Reassembly of Components (Screen) Inside the Trap Body
Part
During Disassembly
During Reassembly
Screen Holder
Remove with a socket wrench
Consult the table of tightening torques
and tighten to the proper torque
Screen Holder
Gasket
Remove the gasket
Replace with a new gasket only if warped
or damaged
Screen
Remove with needle-nose pliers
Insert securely into the trap body