172-65591A-01 (P46UC-Y) 19 Jan 2021
5
Installation
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
The installation procedures shown below are only for the P46UC-Y (trap unit). Please
follow the instruction manual provided by the manufacturer when installing the
connector unit itself.
Applicable connector units: Spirax Sarco PC10, Armstrong standard connector
(neither includes a screen)
(Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.)
1. Install the product, onto the connector unit only if the connector unit is at ambient
temperature and there are no scratches or dirt on the seating surface of the gasket.
2. Before installation, be sure to remove all protective seals.
3. When installing the product onto the connector unit, the universal flange face (for
connecting to the trap unit) must be in the vertical plane, and the trap unit must be
installed with the nameplate facing upwards.
Refer to the
“Detaching / Reattaching the Trap Unit” in the “Disassembly /
Reassembly
” section described later in this manual.
4. Open the inlet and outlet valves and check to make sure that the product functions
properly.
If there is a problem, determine the cause using the “Troubleshooting” section in this
manual.
Installation Examples: Horizontal Piping
Correct
Incorrect
Nameplate is not facing
upwards
Universal Connector Flange is not
in the vertical plane
Ground
Ground
Nameplate
Connector
Flange
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Installation Examples: Vertical Piping
Correct
Incorrect
Nameplate is not facing upwards
Ground
Ground
Nameplate
Connector
Flange
Ground
Ground
Ground
Ground