background image

 

172-65591A-01  (P46UC-Y)    19  Jan  2021

 

15 

BD2 Blowdown Valve Operation

 

 

 

Install properly and DO NOT use this product outside the recommended 

operating pressure, temperature and other specification ranges. 

Improper use may result in such hazards as damage to the product or 

malfunctions which may lead to serious accidents. Local regulations 

may restrict the use of this product to below the conditions quoted.

 

CAUTION 

 

 

Take measures to prevent people from coming into direct contact with 

product outlets. Failure to do so may result in burns or other injury from 

the discharge of fluids.

 

CAUTION 

 

 

Do not use excessive force when connecting threaded pipes to the 

product. Over-tightening may cause breakage leading to fluid 

discharge, which may cause burns or other injury.

 

CAUTION 

 

 

1.  The BD2 valve is in the closed position when the BD2 is shipped from the factory. 

Before attempting to operate the BD2, reconfirm that the BD2 valve is still in the 
closed position. Locate the blow outlet and, during operation, stand to the side and 
well clear of it, as the jet of condensate or steam could cause burns. 

2.  Remain in the area the entire time the BD2 valve is in the open position. Before 

opening the BD2 valve, grip the BD2 valve seat with a wrench and hold firmly in 
place so that it will not rotate when the BD2 valve is loosened. Grip the BD2 valve 
with another wrench and slowly loosen. Condensate and steam will discharge from 
the blow outlet in a jet stream. Be careful not to loosen the BD2 valve so far that it 
becomes removed from the BD2 valve seat. (If the grooved pin becomes damaged, 
large quantities of steam will be discharged in a jet stream.) 

3.  Close the BD2 valve until the flow of fluid completely stops. If the flow of fluid does 

not stop, re-open the valve 

(as in step “2”) to blow out any scale or dirt that may be 

caught in the valve. Re-tighten the valve until the flow of fluid stops completely. 

 

Tightening Torques and Distance Across Flats

 

Part Name 

Torque 

Distance Across Flats 

N

(lbf

ft) 

mm 

(in) 

BD2 Valve

 

30

 

(22)

 

17

 

(

21

/

32

)

 

Screen Holder   

100 

(73) 

30 

(1

3

/

16

(1 N

 10 kg

cm) 

NOTE: Avoid the use of excessive tightening torques, as threaded parts may become damaged. 

Summary of Contents for PowerDyne QuickTrap P46UC-Y

Page 1: ...19 January 2021 Manufacturer 881 Nagasuna Noguchi Kakogawa Hyogo 675 8511 Japan Tel 81 0 79 422 1122 Fax 81 0 79 422 0112 Copyright 2021 by TLV Co Ltd All rights reserved Thermodynamic Steam Trap QuickTrap Trap Unit P46UC Y ...

Page 2: ...t do not have a built in screen Spirax Sarco PC10 Armstrong Standard Connector The universal flange allows the trap to be installed in either horizontal or vertical piping This flexibility greatly reduces the time required for installation and removal as compared to conventional steam traps and also facilitates repair and maintenance operations This PowerDyne thermodynamic steam trap features a bi...

Page 3: ... CAUTION Install properly and DO NOT use this product outside the recommended operating pressure temperature and other specification ranges Improper use may result in such hazards as damage to the product or malfunctions that may lead to serious accidents Local regulations may restrict the use of this product to below the conditions quoted Take measures to prevent people from coming into direct co...

Page 4: ...TLV CK been installed 4 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 5 Has the piping work been done correctly as shown in the figures below Requirement Correct Incorrect Install catchpot with the proper diameter Diameter is too small Make sure the flow of condensate is not obstructed Diameter is too small a...

Page 5: ...ing Temperature TMO Nominal Diameter Maximum Allowable Pressure Maximum Operating Pressure Valve No Minimum Operating Pressure 0 03 MPaG 5 psig Maximum Allowable Back Pressure 80 of the inlet pressure Maximum allowable pressure PMA and maximum allowable temperature TMA are PRESSURE SHELL DESIGN CONDITIONS NOT OPERATING CONDITIONS Valve No is displayed for products with options This item is omitted...

Page 6: ...rained maintenance personnel 1 Install the product onto the connector unit only if the connector unit is at ambient temperature and there are no scratches or dirt on the seating surface of the gasket 2 Before installation be sure to remove all protective seals 3 When installing the product onto the connector unit the universal flange face for connecting to the trap unit must be in the vertical pla...

Page 7: ...heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged The product is quiet and makes no noise and the surface temperature of the product is low Blowing Live steam continually flows from the outlet and there is a continuous metallic sound Steam Leakage Live steam is discharged through the trap outlet together with condensa...

Page 8: ...proper torque Trap Unit Remove the trap unit Follow the special instructions below Fig A Inner Outer Connector Gaskets Remove with a scraper and clean the connector flange with a soft tool Replace with new gaskets to facilitate assembly and prevent loosening of the gaskets apply a small amount of adhesive at 120º intervals around the outer edge of the gaskets Attaching the Trap Unit to the Connect...

Page 9: ...ning torques and tighten to the proper torque Disc Remove being careful not to scratch the lapped surface Make sure that the seat surface lapped side with groove is facing down toward the valve seat Fig B Disc Holder Ring Remove without bending Set on the air vent ring and make sure that it does not sit on the valve seat surface Air Vent Ring Remove without bending as it will not return to its pro...

Page 10: ...tions with anti seize If drawings or other special documentation were supplied for the product any torque given there takes precedence over values shown here Exploded View Nameplate Cover Disc Disc Holder Ring Air Vent Ring Module Valve Seat Inner Module Gasket Outer Module Gasket Trap Body Screen Holder Screen Holder Gasket Screen Connector Flange Inner Connector Gasket Outer Connector Gasket Con...

Page 11: ... of the plug holder making sure the anti seize affixes the gasket tightly to the plug holder Check to make sure the gasket is not caught in the recesses of the threads Hold the plug holder upside down to make sure that the anti seize makes the gasket stick to the plug holder even when the plug holder is held upside down Screw the plug holder by hand into the product body while making sure that the...

Page 12: ...equired Trap operating pressure is below the minimum specified pressure or there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions Steam is discharged or leaks from the outlet blowing steam leakage Rust or scale on the disc or on the module valve seat Clean parts Disc or module valve seat surface damage or wear Replace wi...

Page 13: ...ardous Fluids fluids other than steam air water nitrogen carbon dioxide and inert gases helium neon argon krypton xenon and radon or 11 failure to follow the instructions contained in the TLV Instruction Manual for the Product Duration of Warranty This warranty is effective for a period of the earlier of i three 3 years after delivery of Products to the first end user in the case of sealed SST Ser...

Page 14: ... OTHER COMMERCIAL LOSSES WHERE DUE TO OPERATION OF LAW CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER THIS WARRANTY UNDER ANY OTHER EXPRESS WARRANTY NOT NEGATED HEREBY OR UNDER ANY IMPLIED WARRANTY NOT NEGATED HEREBY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE CANNOT BE EXCLUDED SUCH DAMAGES ARE EXPRESSLY LIMITED IN AMOUNT TO THE PURCHASE PRICE OF THE DEFEC...

Page 15: ...e Such force may break the pin equipped as a valve stopper pin causing a blowout from internal pressure resulting in burns or other injury CAUTION With Blowdown Valve TLV BD2 Configuration Screen Holder Gasket BD2 Valve Seat Screen Holder BD2 Valve Discharge Hole Screen Stopper Pin TLV Blowdown Valve BD2 The BD2 Blowdown Valve installed in the screen area of the trap body uses the trap s internal ...

Page 16: ... and during operation stand to the side and well clear of it as the jet of condensate or steam could cause burns 2 Remain in the area the entire time the BD2 valve is in the open position Before opening the BD2 valve grip the BD2 valve seat with a wrench and hold firmly in place so that it will not rotate when the BD2 valve is loosened Grip the BD2 valve with another wrench and slowly loosen Conde...