172-65606A-02 (JAH5RA-R/JAH7RA-R) 12 Jan 2021
6
Installation
DO NOT use for toxic, flammable or otherwise hazardous fluids. This
product is a drain trap that discharges condensate from air or inert gas
systems. Use only for air or inert gas. This product is for intended use
only. Improper use may result in such hazardous as damage to the
product or malfunctions that may lead to serious accidents.
WARNING
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
Use hoisting equipment for heavy objects (weighing approximately
20 kg (44 lb) or more). Failure to do so may result in back strain or other
injury if the object should fall.
CAUTION
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
1. Before installation, be sure to remove all protective seals.
2. Before installing the product, open the inlet valve and blow out the piping to
remove any piping scraps, dirt and oil. Close the inlet valve after blowdown.
3. Install the product so the arrow on the body is pointing in the direction of flow.
4. The product should be inclined no more than 5° horizontally and front-to-back.
5. Install a condensate outlet valve and outlet piping.
6. To insure proper condensate flow into the trap, remove the balancing line plug
and install a pressure-balancing line. Connect the end of the pressure
–balancing
line to the air/gas main or an area with an air/gas pocket. For more details, see
the section “The Need for a Pressure-balancing Line”.
7. To facilitate inspection and maintenance, install a union or a flange where the
product has connections (inlet, pressure-balancing line, condensate outlet). For
more details, see the section “The Need for a Pressure-balancing Line”.
8. After priming through the pressure-balancing port, open the inlet and outlet valves
and check to make sure that the product functions properly.
If there is a problem, determine the cause using the “Troubleshooting” section in this
manual.
Tolerance Angle for Installation: 5°
Make sure the trap is installed with the raised TLV lettering on the body horizontal.