10 WATT PIR LED Floodlight
15-07-13
Please read these instructions before commencing installation
and retain them for future reference.
Installation Sheet LTFL10PIR
110/240V 10W
IP44
•
Switch off the power source before installation.
•
Install a minimum distance of 1m away from ground.
•
The unit must be installed in the horizontal position (
Figure 1a
), not vertically (
Figure 1b
).
SAFETY PRECAUTIONS
1a
HORIZONTAL
1b
VERTICAL
Figure 1a & 1b
Figure 2
1
2
3
4
CHOOSING A MOUNTING LOCATION
SENSITIVITY TO MOTION
Figure 3
COVERAGE ANGLES
Figure 4
UNIT (M)
WIRING INFORMATION
240V Input Figure 5a
Wired with four
core (w/o plug)
240V Input (Figure 5a)
Brown = Live
Grey = Neutral
Green/Yellow = Earth
Black = Switch Live
MANUAL OVERRIDE FACILITY
In order to manually override the PIR sensor using an
in line switch, the Brown core (Live) is being used
as a permanent feed to the sensor and the Black core
(Switch Live) to be utilized for the switch feed.
(see Figure 5c)
Brown = Live wire - L
Grey = Neutral Wire - N
Green/Yellow = Earth wire - E
Black = Switch Live wire - SL
Switch Live
SL
S1
Manual Override wiring Figure 5c
LED
Floodlight
1. If in doubt consult a professional electrician.
2. Unscrew the floodlight from its wall bracket as indicated in
Figure 2, part 4
.
3. Line up the wall bracket holes and drill three holes into the wall. Use appropriate size rawl
plugs and screws to fix the bracket to the wall.
4. Screw the floodlight on to its wall bracket and tighten firmly, angling the light as required.
5. When connecting the power cable into the PIR sensor housing, please follow the wiring
instructions opposite.
6. After connecting the power supply, the installation has been completed.
INSTALLATION INSTRUCTIONS
•
•
For outdoor installation, a location under eaves is preferable.
•
Avoid aiming the motion sensor at pools, heating vents, air conditioners or objects that may
change temperature rapidly.
•
Do not allow sunlight to fall directly on the front of unit.
•
Try to avoid pointing the unit at trees or shrubs or where the motion of pets may be detected.
•
(
Figure 3
).
•
Select a location for the unit based on the coverage angles shown in
Figure 4
.
For the best results, fix your sensor on a solid surface, 1.8~2.5M above the ground.
When choosing the mounting position consider that the sensor is more sensitive to motion across
the detection field (A) and less sensitive to motion directly towards the sensor (B)
SENSOR
LESS SENSITIVE
SENSOR
MORE SENSITIVE
A
B
The fitting comes pre wired with a 4 core cable to
facilitate a manual override connection as an option.
Should you wish to connect the fitting as a standard
fitting please ignore the black core and connect the
other three cores as follows: Green/yellow should be
connected to earth; grey core to the neutral power input
and brown to the live power input. (see Figure 5b)
As such, referring to Fig 5a simply cancel the black
switch live connection.
STANDARD CONNECTION
Live
Neutral
Earth
L
N
E
LED
Floodlight
Standard wiring Figure 5b
A manual override facility utilizes a second live feed
in order to bypass the sensor thus allowing one to
permanently switch on your flood light.
L
N
E
L'
N
E
Live
Neutral
Earth
L
N
E
L
N
E
L'
N
E
SL
L'