10 WATT PIR LED Floodlight

15-07-13

Please read these instructions before commencing installation 

and retain them for future reference.

Installation Sheet  LTFL10PIR

110/240V 10W

IP44

 

Switch off the power source before installation.

 

Install a minimum distance of 1m away from ground.

 

The unit must be installed in the horizontal position (

Figure 1a

), not vertically (

Figure 1b

).

SAFETY PRECAUTIONS

 

             

              

 1a                    

HORIZONTAL    

               

            1b 

  VERTICAL

  

Figure 1a & 1b

Figure 2

1

2

3

4

CHOOSING A MOUNTING LOCATION

SENSITIVITY TO MOTION

Figure 3

COVERAGE ANGLES

Figure 4

UNIT (M)

 

WIRING INFORMATION

240V Input   Figure 5a

Wired with four
core (w/o plug)

240V Input (Figure 5a)

Brown = Live 

Grey = Neutral

Green/Yellow = Earth 

Black = Switch Live 

 

MANUAL OVERRIDE FACILITY

In order to manually override the PIR sensor using an 
in  line  switch,  the  Brown  core  (Live)  is  being  used 
as a permanent feed to the sensor and the Black core 
(Switch  Live)  to  be  utilized  for  the  switch  feed. 
(see Figure 5c)

Brown = Live wire - L

Grey =  Neutral Wire - N

Green/Yellow = Earth wire - E

Black = Switch Live wire - SL

Switch Live

SL

S1

Manual Override wiring  Figure 5c

LED 

Floodlight

1. If in doubt consult a professional electrician.
2. Unscrew the floodlight from its wall bracket as indicated in 

Figure 2, part 4

.

3. Line up the wall bracket holes and drill three holes into the wall. Use appropriate size rawl 
    plugs and screws to fix the bracket to the wall.
4. Screw  the floodlight on to its wall bracket and tighten firmly, angling the light as required.
5. When connecting the power cable into the PIR sensor housing, please follow the wiring
    instructions opposite. 
6. After connecting the power supply, the installation has been completed.

INSTALLATION INSTRUCTIONS

 

 

For outdoor installation, a location under eaves is preferable.

 

Avoid aiming the motion sensor at pools, heating vents, air conditioners or objects that may 

  change temperature rapidly.

 

Do not allow sunlight to fall directly on the front of unit.

 

Try to avoid pointing the unit at trees or shrubs or where the motion of pets may be detected.

 

 (

Figure 3

).

 

Select a location for the unit based on the coverage angles shown in 

Figure 4

.

For the best results, fix your sensor on a solid surface, 1.8~2.5M above the ground.

When choosing the mounting position consider that the sensor is more sensitive to motion across 

  the detection field (A) and less sensitive to motion directly towards the sensor (B)

SENSOR

LESS SENSITIVE

SENSOR

MORE SENSITIVE

A

B

The  fitting  comes  pre  wired  with  a  4  core  cable  to 
facilitate  a  manual  override  connection  as  an  option. 
Should  you  wish  to  connect  the  fitting  as  a  standard 
fitting  please  ignore  the  black  core  and  connect  the 
other  three  cores  as  follows:  Green/yellow  should  be 
connected to earth; grey core to the neutral power input 
and  brown  to  the  live  power  input.  (see  Figure  5b) 
As  such,  referring  to  Fig  5a  simply  cancel  the  black 
switch live connection.

STANDARD CONNECTION

Live

Neutral

Earth

L

N

E

LED 

Floodlight

Standard wiring  Figure 5b

A manual override facility utilizes a second live feed 
in order to bypass the sensor thus allowing one to 
permanently switch on your flood light.

L

N

E

L'

N

E

Live

Neutral

Earth

L

N

E

L

N

E

L'

N

E

SL

L'