background image

Datalogic Gryphon

  

GM4100 / GD4100 Series – Programming Guide 

 

Datalogic Gryphon

 GM4100 / GD4100 Series: Programming Guide – March 29, 2012 

1

 
GM4100 Syncing 

When using the 

Gryphon

™ 

GM4100

 (wireless) series scanner, after scanning any barcode in this 

document (except when advised to scan both barcodes before syncing), and before proceeding 
with the scanning task, return the scanner to its base to allow the base to sync with the scanner.   

During the sync process lights will flash on the scanner base.  When the lights stop flashing the 
sync is complete.  The sync process typically completes in 10-15 seconds. 

Before You Begin 

Important!

  If the GM4100 (wireless) was previously linked to another base you must 

first

 scan 

the

 Unlink 

barcode at the end of page 2.  

 

 

Whether or not you needed to scan the 

Unlink

 barcode, before you begin using either model 

scanner you must first scan the 

Interface

 

USB Keyboard EM

 barcode below.  

 

 

USB Keyboard Emulator 

Note

: If using the GM4100 (wireless) unit, scan the 

Interface

 

USB Keyboard Em.

 barcode 

below and return the unit to the base to sync.   

After the sync is complete scan the appropiate function barcode on the following pages, taking 
note of the barcode’s accompanying instructions. 

 

³

$ P

,

H A 3

5

,

P

Interface USB Keyboard Em.

 

 

 

Disable Carriage Return 

By default, 

Carriage Return

 <CR> is enabled.  This function should remain enabled if using 

the scanner for circulation purposes.  To use the scanner with

 L.S Cataloging

, you may wish 

to disable 

Carriage Return

.    

Note

:  If using the GM4100 (wireless) unit, scan the appropriate barcode before returning the 

scanner to the base to sync. 
 

³

$ P

, C L F S U 0 0 0 0

, P

Suffix = none

 

 

Enable Carriage Return 

 

³

$ P

, C L F S U 0 D 0 0

,

P

Suffix of CR

 

 

Reviews: