TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura EX Fixed Series |
Installation manual v4.0
14-49
Technical data
Mechanical
Construction
AISI316L Stainless Steel
Finish
Electro-polished
Cable entries
M25x1.5
Electrical
Heater
T[°C] ON = 12 ± 4°C, T[°C] OFF = 20 ± 3°C
Supply voltage
24 V~ 50/60 Hz, 115 V~ 50/60 Hz, 230 V~ 50/60 Hz
Power consumption
25 W Max
Certifications
Weatherproof standard
IP66/IP67
Rating
II 2 G Ex db op pr IIC T6 Gb -
40°C ≤ Tamb ≤ +60°C
II 2 D Ex tb IIIC T85°C Db -
40°C ≤ Tamb ≤ +60°C
II 2 G Ex db op pr IIB T5 Gb -
40°C ≤ Tamb ≤ +75°C
II 2 D Ex tb IIIC T100°C Db -
40°C ≤ Tamb ≤75°C
ATEX Standards
EN 60079-0:2018; EN 60079-1:2014;
EN 60079-28:2015; EN 60079-31:2014
IECEx Standards
IEC 60079-0:2017; IEC 60079-1:2014-06;
IEC 60079-28:2015; IEC 60079-31:2013
INMETRO
ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-28; ABNT NBR IEC 60079-31
UKEX
UKSI 2016:1107 (as amended by UKSI 2019:696)
Schedule 3A, Part 2
Compliancy
CE, UKCA, INMETRO
Certifications EX-FIX IR (Illuminator)
Weatherproof standard
IP66/IP67
Rating
II 2 G Ex db op is op pr IIC T5 Gb -
40°C ≤ Tamb ≤ +40°C
II 2 D Ex tb op is IIIC T100°C Db -
40°C ≤ Tamb ≤ +40°C
II 2 G Ex db op is op pr IIB T4 Gb -
40°C ≤ Tamb ≤ +60°C
II 2 D Ex tb op is IIIC T135°C Db -
40°C ≤ Tamb ≤ +60°C
ATEX Standards
EN 60079-0:2018; EN 60079-1:2014;
EN 60079-28:2015; EN 60079-31:2014
IECEx Standards
IEC 60079-0:2017; IEC 60079-1:2014-06;
IEC 60079-28:2015; IEC 60079-31:2013
INMETRO
ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1;
ABNT NBR IEC 60079-28; ABNT NBR IEC 60079-31
UKEX
UKSI 2016:1107 (as amended by UKSI 2019:696)
Schedule 3A, Part 2
Compliancy
CE, UKCA, INMETRO