MANUFACTURER: 

LLC ТКА SCIENTIFIC INSTRUMENTS  

193144, St. Petersburg, ul. Kirillovskaya 14 

(for correspondence P/O box 234) 

phone (812) 710-74-77; phone/fax (812) 274-74-43 

e-mail: 

[email protected]

 

 

http://www.tka.spb.ru

 

 

Generated by Foxit PDF Creator © Foxit Software

http://www.foxitsoftware.com   For evaluation only.

Summary of Contents for UV-Radiometer

Page 1: ...TKA SCIENTIFIC INSTRUMENTS UV Radiometer UV Operation Manual St Petersburg 2008 Generated by Foxit PDF Creator Foxit Software http www foxitsoftware com For evaluation only...

Page 2: ...are the property of the company TKA SCIENTIFIC INSTRUMENTS and protected by copyright Any full or partial reproduction of this manual s contents is prohibited This publication does not grant any righ...

Page 3: ...stics Wight kg not above with power module 2 0 Operation parameters Ambient temperature normal operation conditions operation temperature range 20 5 0 40 Relative air humidity at ambient temperature25...

Page 4: ...data on the irradiation levels Eee PC 701 is a 7 inch laptop which is a classic notebook with a lockless cover The laptop has no hard disk its function is performed by a 4 Gb flash memory The laptop...

Page 5: ...t an employee of TKA SCIENTIFIC INSTRU MENTS Photometer head Laptop ASUS Eee PC 701 with power unit Cable USB2 0 connecting USB A B Documentation and registration materials Installation of the device...

Page 6: ...of the computer For instance for the device s factory number 14003 the computer s name must be TKA 14003 Note To learn the name of the computer at which you are working you should perform the follow...

Page 7: ...lity Cleaning the device If the device is not in use store it in a dry and clean place Clean the device once a week or when necessary Carefully wipe with a cloth without lint the eye on the photometer...

Page 8: ...dditional adjustment by zones The buttons are not available if the device is not switched up or not found through any reason Program operation Important For the calibration it is necessary to braid in...

Page 9: ...n the selection of the step therefore when the order is infringed failures in operation are possible The selection of the calibration step is effected through pressing the respective button Dark curre...

Page 10: ...rement by pressing the button Measure in current range in the current window of the program When the measurement is completed the program will offer to make a measurement on the next range There are 9...

Page 11: ...ing the range lacing ratios The ratios are calculated following the same scheme as in steps 1 and 2 Place the photometer head in parallel to the plane of the item which is being measured See to it tha...

Page 12: ...on the bench and to make two measurements on adjoining ranges In case it is impossible to increase the signal to the ac ceptable value press the button Low Level and the remaining ratios will be calc...

Page 13: ...evice is installed on the bench so that on the zero range the maximum signal might be obtained in the area of 3 900 4 000 units The position on the bench is fixed the photohead re moved Then in the fi...

Page 14: ...ld of the respective UV zone the measured value is entered and calculation made Above the entry field it is necessary to place a flag for confirming the entry of changes When the flag is removed the c...

Page 15: ...n window of the program contains the signal spectrum and energy characteristics Output of energy characteristics only can be adjusted see item Setup Generated by Foxit PDF Creator Foxit Software http...

Page 16: ...of either display of irradiance only turned on or the mode of simultaneous display of irradiance and signal spectrum turned off In the mode of simultaneous display the irradiance output can be contro...

Page 17: ..._YYYYMMDD_HHMMSS The obtained file can be downloaded into any word processor or electronic table for further processing Storage and transportation rules The device must be stored in a dry heated room...

Page 18: ...cal support services the manufacturer has the right to require from you the information relating to the technical parameters of your equipment The manufacturer has the right to use the above informati...

Page 19: ...he Software TKA SCIENTIFIC INSTRUMENTS designated representatives v publish the Software or any License Num ber or use the same other than for the purposes described in Section 1 a of this Agreement v...

Page 20: ...sole and exclusive remedy for breach of this Warranty is replacement of the defective media or Software or at TKA SCIENTIFIC INSTRUMENTS option return of the Soft ware for a full refund In order to ex...

Page 21: ...ter hereof d Amendments Waiver This Agreement may be modified or changed in whole or in part in any manner in writing duly signed by both parties hereto or by a further electronic agreement presented...

Page 22: ...number on the device is modified erased removed or dam aged The warranty gives no right for recovery of indirect damage resulted from the failure of the de vices under warranty When the device fails...

Page 23: ...St Petersburg ul Kirillovskaya 14 for correspondence P O box 234 phone 812 710 74 77 phone fax 812 274 74 43 e mail info tka spb ru http www tka spb ru Generated by Foxit PDF Creator Foxit Software h...