Program operation 

Place the photometer head in parallel to the plane of the item which is being measured. See to it that 
the  shadow  of  the  operator  who  conducts  the  measurement  does  not  cast  itself  onto  the  photohead 
window, as well as the shadow of any irrelevant objects that are temporarily present. 
Upon being started, the program scans the USB bus and in case the device is detected displays 

Ready

 

in the status line and starts automatically to display the data received from the photohead. When there 
is no connection, the program displays 

Searching… 

in the status line. 

The four buttons of the control panel are designed for storing data being received into a text file, the 
spectrum graph into a file, setting up the program, and outputting additional information correspond-
ingly. The spectrum graph is stored in BMP format.  
For the user’s convenience data are stored into a text file also through pressing the button 

ENTER

.  

 

The 

name 

of 

the 

file 

in 

this 

case 

is 

formed 

automatically 

in 

the 

format 

tka_data_YYYYMMDD_HHMMSS

. The obtained file can be downloaded into any word processor 

or electronic table for further processing. 
 
 

Storage and transportation rules 

The device  must  be  stored  in  a dry  heated room  under  the  conditions corresponding  to the group  1 
GOST15150-69 at the tempe5 to +40 

0

С and relative humidity not above 85% at 25

0

С. 

The air in the room should not contain admixtures of aggressive vapors or gases. 
The transportation of the devices in the manufacturer’s packing can be made by any closed transport 
without  speed  limitations GOST  15150-69  at the ambient  temperature  from  10 below zero to  60 

0

С 

above zero and relative humidity up to 98% at the temperature 35 

0

С. After transportation at tempera-

ture below 0

0

С it should be unpacked should only be effected after holding it in the packed condition 

at the temperature (20±5) 

0

С for at least 12 hours. 

Air transportation is not allowed. 
 

An acceptance certificate 

The device UV-Radiometer ТКА-UV, factory No. 
                                    is acknowledged ready for operation. 

 

Date of release: “____” _______ 200 

 

Stamp  QCD: ___________________________________ 

 

Date of sale: “____” _____________ 200___  
 

Generated by Foxit PDF Creator © Foxit Software

http://www.foxitsoftware.com   For evaluation only.

Summary of Contents for UV-Radiometer

Page 1: ...TKA SCIENTIFIC INSTRUMENTS UV Radiometer UV Operation Manual St Petersburg 2008 Generated by Foxit PDF Creator Foxit Software http www foxitsoftware com For evaluation only...

Page 2: ...are the property of the company TKA SCIENTIFIC INSTRUMENTS and protected by copyright Any full or partial reproduction of this manual s contents is prohibited This publication does not grant any righ...

Page 3: ...stics Wight kg not above with power module 2 0 Operation parameters Ambient temperature normal operation conditions operation temperature range 20 5 0 40 Relative air humidity at ambient temperature25...

Page 4: ...data on the irradiation levels Eee PC 701 is a 7 inch laptop which is a classic notebook with a lockless cover The laptop has no hard disk its function is performed by a 4 Gb flash memory The laptop...

Page 5: ...t an employee of TKA SCIENTIFIC INSTRU MENTS Photometer head Laptop ASUS Eee PC 701 with power unit Cable USB2 0 connecting USB A B Documentation and registration materials Installation of the device...

Page 6: ...of the computer For instance for the device s factory number 14003 the computer s name must be TKA 14003 Note To learn the name of the computer at which you are working you should perform the follow...

Page 7: ...lity Cleaning the device If the device is not in use store it in a dry and clean place Clean the device once a week or when necessary Carefully wipe with a cloth without lint the eye on the photometer...

Page 8: ...dditional adjustment by zones The buttons are not available if the device is not switched up or not found through any reason Program operation Important For the calibration it is necessary to braid in...

Page 9: ...n the selection of the step therefore when the order is infringed failures in operation are possible The selection of the calibration step is effected through pressing the respective button Dark curre...

Page 10: ...rement by pressing the button Measure in current range in the current window of the program When the measurement is completed the program will offer to make a measurement on the next range There are 9...

Page 11: ...ing the range lacing ratios The ratios are calculated following the same scheme as in steps 1 and 2 Place the photometer head in parallel to the plane of the item which is being measured See to it tha...

Page 12: ...on the bench and to make two measurements on adjoining ranges In case it is impossible to increase the signal to the ac ceptable value press the button Low Level and the remaining ratios will be calc...

Page 13: ...evice is installed on the bench so that on the zero range the maximum signal might be obtained in the area of 3 900 4 000 units The position on the bench is fixed the photohead re moved Then in the fi...

Page 14: ...ld of the respective UV zone the measured value is entered and calculation made Above the entry field it is necessary to place a flag for confirming the entry of changes When the flag is removed the c...

Page 15: ...n window of the program contains the signal spectrum and energy characteristics Output of energy characteristics only can be adjusted see item Setup Generated by Foxit PDF Creator Foxit Software http...

Page 16: ...of either display of irradiance only turned on or the mode of simultaneous display of irradiance and signal spectrum turned off In the mode of simultaneous display the irradiance output can be contro...

Page 17: ..._YYYYMMDD_HHMMSS The obtained file can be downloaded into any word processor or electronic table for further processing Storage and transportation rules The device must be stored in a dry heated room...

Page 18: ...cal support services the manufacturer has the right to require from you the information relating to the technical parameters of your equipment The manufacturer has the right to use the above informati...

Page 19: ...he Software TKA SCIENTIFIC INSTRUMENTS designated representatives v publish the Software or any License Num ber or use the same other than for the purposes described in Section 1 a of this Agreement v...

Page 20: ...sole and exclusive remedy for breach of this Warranty is replacement of the defective media or Software or at TKA SCIENTIFIC INSTRUMENTS option return of the Soft ware for a full refund In order to ex...

Page 21: ...ter hereof d Amendments Waiver This Agreement may be modified or changed in whole or in part in any manner in writing duly signed by both parties hereto or by a further electronic agreement presented...

Page 22: ...number on the device is modified erased removed or dam aged The warranty gives no right for recovery of indirect damage resulted from the failure of the de vices under warranty When the device fails...

Page 23: ...St Petersburg ul Kirillovskaya 14 for correspondence P O box 234 phone 812 710 74 77 phone fax 812 274 74 43 e mail info tka spb ru http www tka spb ru Generated by Foxit PDF Creator Foxit Software h...

Reviews: