Titon® Recommend

1. 

Any flexible ducting used must be pulled taught;

2. 

Ducting must be installed in such a way that resistance to airflow is minimised;

3. 

Duct joints to the unit’s duct ports must be fixed using a method that ensures a long term seal is achieved.

Handling

1. 

Before off-loading products, please ensure that the means of transport/ lifting is suitable to accommodate the 
required weight and size capacity;

2. 

Manually handle unit in accordance with the 89/391/EEC-OSH standard (and associated updates) and/or local 
regulations.

Packing Contents

Inspect the unit when taking delivery.  Check the unit for damage and that all accessories have been supplied. 
Package supplied with:-

 

ƒ

Trimbox NO

2

 Filter® system; 

 

ƒ

Product Manual x 1;

 

ƒ

3mm Hex Key with inset magnet x 1.

Any shortages or damage must be immediately reported to the supplier

Summary of Contents for TP 556

Page 1: ...Product Manual ventilation systems Trimbox NO2 Filter UNIT ONE TP550 220x90 TP552 160 TP554 150 TP 556 180 UNIT TWO TP551 220x90 TP553 160 TP555 150 TP557 180 EN...

Page 2: ...e present or occur Excessive oil or grease laden atmosphere Corrosive or flammable gases liquids or vapours Ambient temperatures above 80 C or below 5 C Humidity levels above 90 or is a wet environmen...

Page 3: ...that the means of transport lifting is suitable to accommodate the required weight and size capacity 2 Manually handle unit in accordance with the 89 391 EEC OSH standard and associated updates and or...

Page 4: ...Connection 9 Ducting Behind Unit 9 Maintenance 10 Filter Replacement 10 Prefilter 10 Active Carbon Filters 10 NO2Testing Kit 10 Carbon Life Prediction Service 10 How to Change Filters 11 Disposal of F...

Page 5: ...ation measures to improve the indoor air quality IAQ The Titon Trimbox NO2 Filter is an effective means of reducing high NO2 levels down to an acceptable level of 40 g m3 as a mean annual concentratio...

Page 6: ...Unit Dimensions excluding ports Service Void 6 Dimensions Port Size s Rectangular Ports 220mm x 90mm Round Ports 150mm 160mm and 180mm 350 604 2 0 5 4 0 0...

Page 7: ...re maintenance Do not box in the unit making access to the unit difficult for maintenance and repair Mounting 1 Mark positions of the mounting holes onto the mounting surface using dimensions as shown...

Page 8: ...strate and the weight of the unit Fixings are not supplied due to the variation in materials For advice on suitable fixings contact your local specialized fixings dealer 4 When fitting screws position...

Page 9: ...pplied without a prefilter it is very important that it is fitted so air supplied to the Trimbox Filter is from a HRV with integrated filters Ducting Connection The Trimbox Filter has labels with icon...

Page 10: ...ntaining the NO2 filter to be in use This will give an accurate result for the performance of the NO2 filter If the levels of NO2 are greater than 40 g m3 then the filter should replaced The 8hr expos...

Page 11: ...do not over tighten 5 Replace Pre Filter by sliding back into casing Ensure the airflow direction corresponds with the direction arrow on filter Disposal of Filters The carbon within the filters are i...

Page 12: ...ort the weight of the unit The insulation jacket can be opened by means of hook and loop fasteners on flaps at the front and this will give access to the filters for inspection and replacement Model P...

Page 13: ...ber Ducting Behind Unit Mounting Kit All Models TP558 NO2 Testing Kit A NO2 testing kit is available from Titon that can be used to determine the levels of NO2 within the property NO2 Testing Kit Expo...

Page 14: ...14 Service Record Log Serviced By Company Date Notes...

Page 15: ...15 Serviced By Company Date Notes...

Page 16: ...3126 Email ventsales titon co uk Web www titon com 2017 TITON DO 5446 Iss 04 In the event of any queries please contact the system installer Ensure this booklet is passed to the householder once insta...

Reviews: