Page 1: ...ventilation systems aurastat V TP526 HRV Controller Product Manual EN ...

Page 2: ...SUMMERboost 6 Summer By Pass 6 Duct Heater Control 6 2 x Proportional Sensor Inputs 6 3 xVolt Free Inputs 6 2 x Live Switch Inputs 6 Frost Protection Program 6 HRV RunTimer 6 Holiday Mode 6 Multiple InternalTemperature Sensors 6 Installation Fitting 7 aurastat V 7 Wiring Connections Access 7 aurastat V 7 HRV 7 Wiring Diagram 7 User Interface Buttons 8 Display 8 Display Icons 9 Menu System 9 Menu S...

Page 3: ...18 24AWG Stranded Tinned Copper 6 Control communication cables should not be placed within 50mm or on the same metal cable tray as any 230V lighting or power cables 7 Ensure all cable glands are fully tightened 8 The unit must be stored in a clean and dry environment Do not install the appliance in areas where the following may be present or occur Excessive oil or a grease laden atmosphere Corrosi...

Page 4: ...aurastat V 4 ...

Page 5: ...up Day of Week Display The aurastat V displays the days of the week as numbers Backlight Brightness The aurastat V display backlight brightness can be adjusted or turned off Boost Overrun Timer A programmable timer that controls the time the HRV remains at Boost Speed after all boost switches have been released Boost Delay Timer A programmable timer which can be used to delay the HRV running at Bo...

Page 6: ...the extracted stale air Summer Bypass operation is automatically controlled The Summer Bypass mechanism diverts the stale air being extracted from the dwelling around the heat cell so that its heat energy is not transferred to the fresh air being supplied to the dwelling Duct Heater Control To maintain ventilation flow rates where prolonged periods of very low temperatures occur the facility for t...

Page 7: ...ited to the wall type or if using a metal box using M3 5 raised countersunk machine screws Wiring Connections Access aurastat V The front of the unit is removed by loosening a single screw on the bottom face to the unit lifting the bottom of the front away from the base and unhooking the top of the front from the base The base has a cable access knockout Communication Cable Unshielded 4 Core 18 24...

Page 8: ... The display uses a mixture of icons text and figures grouped into regions to communicate information to the user SETUP key ARROW keys keys HOME key FAN key Enter menu item Enter parameter setting Previous Next menu item Navigation Increase Decrease parameter Back to Setup Menu Enter setup Switch between Fan Speed display Temprature monitoring Cycle though Clock RH Room Sensor s Long Press engage ...

Page 9: ...access to the control and monitoring functions Gives access to settings likely to be routinely used by the householder Gives access to settings likely to be used by Maintenance or Service Engineers Gives access to advanced settings required during installation and commissioning Pass code protected Gives access to the reset function Pass code protected Status Alert Duct Heater Frost Program active ...

Page 10: ...ge Interval o Speed 4 SUMMERboost o o Boost Alert On Off o Boost Alert Timer o Summer Mode Enable Disable o Summer Mode o Summer By Pass Enable Disable o Summer By Pass o Duct Heater Enable Disable o Duct Heater o Room Sensor 1 Set Points o Room Sensor 2 Set Points o Internal Humidity Boost On Off o Internal Humidity Boost Full o Contious SPEED2 o Boost SPEED3 o Setback SPEED4 o Frost Protection o...

Page 11: ...e The Quick Start Guide explains step by step how to set up 1 Time 2 Day 3 Continuous Speed 1 4 Boost Speed 3 Step Action Button Press es Screen s 1 Power up the HRV Run Mode 2 Enter SETUP Press key 3 Enter SETUP1 menu Press key SETUP key ARROW keys keys HOME key FAN key Enter menu item Enter parameter setting Previous Next menu item Navigation Increase Decrease parameter Back to Setup Menu Enter ...

Page 12: ...s key to enter hours and move to next menu item 7 Enter Day setup Press key to enter day setup 8 Change Day Using edit day Press key to enter Day and move to next menu item 9 Exit SETUP1 menu Press key to return to SETUP1 menu 10 Enter SETUP3 menu Move to SETUP3 menu by pressing key twice Press key to enter SETUP3 menu 11 Enter Pass Code Using edit the individual digits Use to move digits Press ke...

Page 13: ...ase to modify the decimal Press and hold to modify the integer Press key to enter value and move to DONE 15 Finish Continous SPEED2 setup Press key to enter values and move to the next menu item SETUP key ARROW keys keys HOME key FAN key Enter menu item Enter parameter setting Previous Next menu item Navigation Increase Decrease parameter Back to Setup Menu Enter setup tch between Fan Speed displa...

Page 14: ...ld to modify the integer Press key to enter value and move to next menu item 18 Edit Boost Extract Rate Using edit extract rate Press and release to modify the decimal Press and hold to modify the integer Press key to enter value and move to DONE 19 Exit SETUP3 Press key to enter values and move to the next menu item Press key twice to exit SETUP3 menu and return to Run Mode 20 Run Mode 14 ...

Page 15: ...Setpoint 30 89 70 SETUP2 Configurable Item Range Default Additional information Min Max Filter Change Interval 3 months 24 months 12 months Boost Overrun Timer Kitchen 0 mins 60 mins 15 mins Wet Room 0 mins 60 mins 15 mins Boost Overrun timers are set independently for Kitchen and Wet Room inputs Boost Overrun timers must be set greater than zero for any momentary switch or the aurastat s fan butt...

Page 16: ...nabled Disabled Enabled Duct Heater Enable Disable Enabled Disabled Disabled Duct Heater Frost User Frost Selects sensor that controls Duct Heater activity Frost FRST Uses sensor on the to atmosphere side of the heat cell and the Frost Protection Threshold temperature configured in SETUP3 User Uses sensor in the From Atmosphere OUTSIDE airstream and user configured Duct Heater threshold temperatur...

Page 17: ...Dynamic Dynamic 60 Sensor Min Max values are setup in SETUP3 menu Recommended Default High Low Values for sensors Sensor Type Titon Part SP Low SP high C TP543 0017 0027 CO PPM TP541 0800 1400 AQ PPM TP540 0800 1400 RH TP542 0060 0070 Set point High Dynamic Dynamic 70 Room Sensor 2 na na CO These settings are only available when Room Sensor2 is enabled in SETUP3 menu Room Sensor 2 is setup by defa...

Page 18: ...red to configure settings in the SETUP3 menu Continuous SPEED2 Supply 14 100 40 Extract 14 100 40 Boost SPEED3 Supply 14 100 70 Extract 14 100 70 Setback SPEED1 Supply 14 100 18 Extract 14 100 18 Press and release the key to modify the mantissa decimal Press and hold the key to modify the characteristic integer HRV fan speed will change to reflect the displayed setting when the button is released ...

Page 19: ...nt Frost Protection activates turning off the Supply fan Reduce When temperature detected is below Frost set point Frost Protection activates progressively reducing the speed of the Supply fan until the temperature reaches 4 C below Frost set point at which point the Supply fan is stopped Room Sensor 1 Enable Disable Enable Disable Disable Activates Setup Room Sensor 1 in SETUP2 menu Room Sensor T...

Page 20: ...1850PPM 0000 9999 Continous SPEED 2 Proportional Increase 450 Sensor Min Point 0V 1850 Sensor Max Point 10V 800 Set Point Low 1400 Set Point High Boost SPEED 3 Switch Input 1 Boost from Kitchen Options are Boost from Kitchen Boost from Wet Room Setback Summer Mode Engage SUMMERboost Disable Switch Input 2 Boost from Wet Room Switch Input 3 Summer Mode Engage SUMMERboost Disable Live Switch 1 LS1 B...

Page 21: ...4 C Configurable Item Default Room Sensor 1 Set point Low 0060 Set point High 0070 Room Sensor 2 Set point Low 0800 Set point High 1400 Internal Humidity Boost Off RH Boost Set point 70 RH Boost Overrun timer 15 RH Boost Hysterisis 1 SETUP3 Configurable Item Default Continous SPEED2 Supply 40 Extract 40 Boost SPEED3 Supply 70 Extract 70 Setback SPEED1 Supply 18 Extract 18 SPEED4 SUMMERboost Supply...

Page 22: ... 2 Setup Time Setup Day of week Setup Backlight Setup Boost Overrun Timer SETUP key ARROW keys keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu 22 ...

Page 23: ...n Setup Boost Delay Timer Boost Inhibit On Off 23 ...

Page 24: ...Setup Boost Inhibit Times Done Setup Internal Humidity Boost Partial SETUP1 2 of 2 24 ...

Page 25: ...SETUP key ARROW keys keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu 25 ...

Page 26: ... ARROW keys keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu Run Timer Filter Change Reset Setup Filter Change Interval Setup Boost Overrun Timer 26 ...

Page 27: ...n Setup Boost Delay Timer Setup Speed 4 SUMMERBoost Boost Alert On Off 27 ...

Page 28: ...rt Timer Summer Mode Enable Disable Setup Summer Mode SETUP2 2 of 4 SETUP key ARROW keys keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu 28 ...

Page 29: ...Summer By Pass Enable Disable Setup Summer By Pass 29 ...

Page 30: ...Duct Heater Enable Disable Setup Duct Heater Setup Room Sensor 1 repeat for Room Sensor 2 SETUP2 3 of 4 30 ...

Page 31: ...s are only available in this menu when enabled in SETUP3 Internal Humidity Boost On Off SETUP key ARROW keys keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu 31 ...

Page 32: ...SETUP2 4 of 4 Setup Internal Humidity Boost Full Done 32 ...

Page 33: ...SETUP key ARROW keys keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu 33 ...

Page 34: ...Setup Continous SPEED2 Setup Boost SPEED3 Setup Setback SPEED1 SETUP key ARROW keys keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu Passcode 3333 34 ...

Page 35: ...ack Setup Boost Overrun Timer Setup Boost Delay Timer Setup SUMMERBoost SPEED4 35 ...

Page 36: ...SETUP3 2 of 2 a c a c Setup Frost Protection Room Sensor 1 Enable Disable repeat for Room Sensor 2 Setup Room Sensor 1 repeat for Room Sensor 2 36 ...

Page 37: ...repeat for Switch Input 2 3 Setup Live Switch 1 repeat for Live Switch 2 Done SETUP key ARROW keys keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu 37 ...

Page 38: ...s keys HOME key Enter menu item Enter parameter setting Previous Next menu item Increase Decrease parameter Back to Setup Menu Selecting Yes returns ALL configuable values except commissioned fan speeds to the default values and returns to SETUP1 menu Passcode 6840 38 ...

Page 39: ...ol that is used between the aurastat and the HRV unit The above 7 error codes indicate a comms error between the aurastat and the HRV unit check the wiring and connections 13 Thermistor 1 error Problem with thermistor in Extract from dwelling airstream 14 Thermistor 2 error Problem with thermistor in To Atmosphere airstream 15 Thermistor 3 error Problem with thermistor in From Atmosphere airstream...

Page 40: ...the ventilation system is complete This Product Manual must be kept in the Home Information Pack Important environmental information about this product This symbol on this unit or the package indicates that disposal of this unit after its lifecycle could harm the environment Do not dispose the unit as unsorted municipal waste it should be disposed by a specialized company for recycling This unit s...

Reviews: