TA 250 / TA 450
(0001)
61
/
112
11. Troubleshooting
Fault
Cause
Remedy
The tool is blocking during the
operation, or the welding
process, due to this fact it isn’t
possible to extract the tool from
the strap.
The sealing mechanic is
blocking.
Remove and reinsert the the Li-Po
battery straight. The blockade
should be dissolved because the
control system moves the sealing
mechanism in basic position.
Should the fault not have been
remedied, contact TITAN service
dept.
Li-Po storage battery plugged
into tool, but the tool doesn’t
work.
Li-Po storage battery defective
or insufficiently charged.
Check charge of Li-Po storage
battery and recharge or, if required,
replace it.
Contacts of Li-Po storage
battery or the tool polluted or
defective.
Visual inspection of the contacts;
clean and straighten them, if
required.
Loose cable connections.
Check the cable connections and fix
them if required.
Progressive abatement of Li-Po
storage battery duty cycles.
Li-Po storage battery defective
or insufficiently charged.
Check charge of Li-Po storage
battery and recharge or, if required,
replace it. Then use the charged Li-
Po storage battery again and check
(count) if there is an improved cycle
time.
Life of Li-Po storage battery
moves towards its end, internal
cells are defective or exhausted.
Use new Li-Po storage battery.
Charger does not start charging
and/or flashes red.
Contacts of Li-Po storage
battery or the tool polluted or
defective.
Visual inspection of the contacts;
clean and straighten them, if
required.
Netzstecker des Ladegerätes
nicht in der Steckdose, oder
Ladegerät defekt.
Prüfen ob Netzstecker in Steckdose
steckt, ggf. einstecken. Ladegerät
auf Funktion prüfen.
Li-Po storage battery is
defective.
Do not use the Li-Po storage battery
any further and replace it with a new
Li-Po storage battery.
Voltage of the Li-Po storage
battery is below 10 V.
Test charger for proper function with
an instrument check, if voltage
below 10 V therefore charging is not
allowed. Replace Li-Po storage
battery.
Work parameters like tensioning
force and welding time cannot
be entered and/or do not remain
saved.
Operator panel
(104)
or circuit
board control
(102)
is defective.
Replace parts and/or contact TITAN
– Service.
Pressing the push-button 2
doesn’t start the welding
operation.
Push-button 2, welding motor
(503)
and/or circuit board
(19)
defective, or loose cable
connection.
Visual check for loosen cable
connection, re-establish the cable
connection if required. Replace
parts when damage becomes visible
and/or contact TITAN-Service.
H TA 250 / 450 EU 38/15
Summary of Contents for TA 250
Page 34: ...TA 250 TA 450 0001 34 112 12 Konformitätserklärung H TA 250 450 EU 38 15 ...
Page 64: ...TA 250 TA 450 0001 64 112 12 Declaration of conformity of the machine H TA 250 450 EU 38 15 ...
Page 95: ...TA 250 TA 450 0001 95 112 12 Déclaration CE de conformité des machines H TA 250 450 EU 38 15 ...
Page 98: ...TA 250 TA 450 0001 98 112 13 2 TA 450 B TA 250 TA 450 EU 38 15 13 16mm 1 2 5 8 ...
Page 100: ...TA 250 TA 450 0001 100 112 B TA 250 TA 450 EU 38 15 ...
Page 106: ...TA 250 TA 450 0001 106 112 B TA 250 TA 450 EU 38 15 ...