The panel below shows the main menu function icons of the Interface as seen on the top left-
hand bar of the screen.
4.1.2. Retrieve Settings from Meter
When connected the settings will normally be automatically retrieved from the meter. If this is
not the case, or the user wishes to check the meter saved settings against those shown in the
software, they can be retrieved from the nonvolatile memory of the flow meter by pressing the
looking glass icon.
4.1.3. Test Outputs
This tab enables the user to manually set
outputs on the Pins for testing to the
target device.
Once the required output is selected click
the “Start Test” button and
all pins will
give the selected output rate for 23
seconds.
4.1.4. Diagnostic Tools
This section can be used with Titan Enterprises assistance for updating software and settings
as well as creating diagnostic log files of the ultrasonic meter’s performance.
Save
settings to meter’s non
-volatile memory
Test outputs
Load settings from a file on the computer
Diagnostic tools
Save settings to a file on the computer
Software Information
Retrieve settings from meter