TPM 053
Version 1.0, May 30, 2017
Page | 34
TROUBLESHOOTING & MAINTENANCE
Gateway Installation and Operation Manual
Gateway Troubleshooting
The following diagnostic checklist provides guidance for troubleshooting basic operation and electrical
system problems.
Indication
Condition
Resolution
Status light is on
–
solid
Internal Gateway
failure
Contact Titan
Status light is off
Power is not turned
ON, electrical failure
or internal Gateway
failure
1.
Confirm adequate power supply and
adequate operating voltage at the power
and ground terminals to the following
components:
•
Finch II display
•
Gateway
2.
Verify all cables are connected and wires
are secure on the connections below:
•
Gateway interconnect cable to the
junction box
•
Power supply wiring
•
Internal junction box wiring
•
Gateway to Finch II wiring
3.
Contact Titan
Status light is ½
second on, ½
second off
Gateway is operating
Continue with the diagnostics below