Titan Logix Corp TD80 Installation Quick Reference Sheet Download Page 1

STEP 1: 

Program the TD80 and Finch II Display. 

See TPM 001 Section 6.3 and TPM 010 Sections  3 
and 10 for Details.  

MECHANICAL INSTALLATION 

STEP 3: 

Align & Weld the Anchor Cone. 

See TPM 001, Section 2.4 for Details. 

STEP 2: 

Align & Weld the 1” NPT Top  

Fitting (Collar). See TPM 001, Section 2.4 for Details. 

STEP 4: 

Install the Probe. See TPM 001 Section 2.4 for Details. 

Measure Height from Top of 1” 

NPT Fitting to Bottom of Tank 

Inside Anchor Cone. 

Cut the Probe Length to 

 1 1/2”. 

Install the Probe without 

Twisting or Bending. 

A. 

B. 

C. 

STEP 5: 

Mount the 
Transmitter. 
Hand Tighten 
the Transmitter 
Nut down to 
the O-Ring, 
then Tighten 
with a Wrench 
until secure.  
See TPM 001, 
Section 2.4 for 
Details. 

STEP 6: 

Mount the Finch Display. See  

TPM 001, Section 2.4 for Details. 

STEP 7: 

Mount the Alarm Accessories (optional).  

See TPM 001, Section 2.4 for Details. 

STEP 8: 

Inspect the Mechanical Installation. See TPM 001, Section 2.4 for Details. 

1.  All Welding 

2.  Components Mounted in Correct  

Location 

3.  Component Damage 

4.  All Nuts and Bolts Securely Tightened 

5. 

Clean All Debris

 

Titan Logix Corp.  | Titan Logix USA Corp. | Head Office: Edmonton, Alberta, Canada 780.462.4085  

 Toll Free 1.877.462.4085 | TSX-V: TLA www.titanlogix.com 

Probe 

Installation:

  

 

The  probe  has  been 
cut to the proper length 
when it is fully threaded 
into  the  top  fitting  with 
a  ½”  gap  between  the 
bottom  of  the  tank  and 
end of the probe at the 
shorting  block,  inside 
the anchor cone. 

 

TITAN LOGIX TIPS 

PROGRAMMING 

 

TD80™ and FINCH II Installation  

Quick Reference Sheet 

Horn 

Lights 

NOTE: 

All installation steps are to be performed in accordance 

with  the  TD80  Product  Manual,  TPM  001,  and  the  FINCH  II  
Installation & Operation Manual, TPM 010 . 

(TPM 019/ Rev 1.1/ October 8, 2014)

 