11
7-OPERATION INSTRUCTIONS
WARNING: LIFT OPERATION BY TRAINED AUTHORIZED PERSONNEL OVER
18 YEARS ONLY. APPLY THE PARKING BRAKE AFTER POSITIONING THE VEHICLE
ON THE LIFT. DO NOT ALLOW ANYONE TO STAY IN LIFT AREA DURING RAISING
AND LOWERING CYCLES. CLOSELY WATCH THE VEHICLE AND THE LIFT DURING
RAISING AND LOWERING CYCLES. OBSERVE THE RATED LOAD CAPACITY AND
LOAD DISTRIBUTION. DO NOT ALLOW ANYONE TO CLIMB ON LIFT OR STAY
INSIDE VEHICLE. AFTER RAISING THE VEHICLE FRAME 6”, STOP AND CHECK
ADAPTERS FOR SECURE CONTACT. PERFORM BUMPER TEST(PG.2). MAKE SURE
THE VEHICLE DOORS ARE CLOSED DURING RAISING AND LOWERING CYCLES.
WARNING: IN CASE OF DEFECTS OR MALFUNCTIONS SUCH AS JERKY LIFT
MOVEMENT OR DEFORMATION OF THE SUPERSTRUCTURE, SUPPORT OR LOWER
THE LIFT IMMEDIATELY. CONTACT QUALIFIED SERVICE PERSONNEL.
WARNING: PAY CLOSE ATTENTION WHEN SETTING THE LOCKS. THE LOCKS
MUST BE A LEVEL MATCH SET IN ORDER TO AVOID A VEHICLE TILT.
WARNING: ALWAYS LOCK THE LIFT BEFORE GOING UNDER THE VEHICLE.
NEVER ALLOW ANYONE TO GO UNDER THE LIFT WHEN RAISING OR LOWERING.
7.1 DEFECTS / MALFUNCTIONS
7.2 CONTROLS
7.2.1 UP CONTROL
7.2.2 SAFETY LOCK CONTROL
The safety latch mechanism will “Trip Over” as the lift raises and drop into each safety latch
stop. To lock the lift you must press the lowering handle on the power unit (Fig. 1 pg. 13) to
relieve the hydraulic pressure and let the safety locks engage into a level locked position.
Once the up button is actuated, the lift moves up until the button is
released or the limit stop is reached�
UP