• Check that all equipment that will be activated by this controller is the
proper voltage(s).
• Verify that the equipment you are controlling does not exceed a total of
14.5 amps.
• This controller is designed for “inside use” only.
• Avoid placing the controller near heat generating sources such as a CO
2
Generator.
• Use caution if operating controller in extremely humid environments (90%
and above).
• Do not use controller for purposes other than the unit was designed to
function.
• Use controller within defined environmental specifications.
• Ask your Dealer for tips and techniques regarding the use of this controller.
• Be conscientious when disposing of any products.
Factory Settings
• CO
2
PPM Setting: 1000 ppm
• CO
2
Dead-band: 50 ppm
• Calibrate CO
2
PPM: 400 ppm
• CO
2
Mode: PPM UP
Basic CO
2
Controller Overview
The Basic CO
2
Controller has an adjustable CO
2
set point, a 15 foot sensor
cord attached to an accurate CO
2
sensor and equipped with a photocell that
detects day/night conditions and will automatically disable the load output of
the CO
2
controller during nighttime conditions. This controller has CO
2
ppm
increase, fuzzy logic and CO
2
ppm decrease functions.
Instructions for Operation
CO
2
PPM Setpoint
Press the knob and turn to set, press again to confirm the setting.