TIP TIPINF001 User Manual Download Page 1

1.Introduction

Tripod mounting hole

Switch

USB interface

Double-sided adhesive area

Hanging hole

Nameplate

Mode switch hole

Infrared thermometer

Infrared ranging sensor

Temperature display

Alarm light

2.Specification

1. Accuracy: ±0.2 degrees

34

45

℃,

place it in the operating environment for 30 

minutes before use

2. Abnormal automatic alarm: fl“Di Di” sound

3. Automatic measurement: measuring distance 5cm ~ 10cm

4. Screen: Digital display

5. Charging method:USB charging or battery(18650 Li-ion).

6. Install method: nail hook, double-sided adhesive sticking, bracket fixing

7. Environment temperature: 10

~40

℃(

Recommended 15

~35

℃)

8. Infrared measuring range: 0

50

9. Response time: 0.5s

10. Input: DC 5V

11. Weight: 350g

12. Dimensions: 170*115*140mm

13. Standby

About one week

14. Counting capacity: 999

3.Status Description

4.Operation Instruction

1. Standby:  The red dot in the bottom of the display lights up in turn. (Fig. 1) 
2. Insufficient power: The horizontal bar lights up in the middle of the display. (Fig. 2) 
3. Normal temperature: Flashing green lights and alarm ‘Di’. (Fig. 3)

4. Abnormal temperature: Flashing red lights and alarm ‘Di Di’.(Fig. 4) 

5. Default

bod:object mode

):

      ‘Lo’: Ultra-low temperature alarm. (Fig.5) 

      ‘HI’ : Ultra-high temperature alarm.(Fig. 6)

1. Temperature measurement: Front of the thermometer and approach it within 5-10 cm. 

(Fig. 7)

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Fig. 7

5~10cm

2. Mode switching: There is a small hole on the back of the device (Fig. 8). You can use a

3mm diameter screwdriver to insert the hole and then press the button.

  (1) Temperature unit: Press ‘mode switch hole’ then select ‘C’ or ‘F’ (Fig.9, 10)   C: Celsius
        F: Fahrenheit

(2) Mode: Long press mode switch hole for 3 seconds to switch the temperature 

     measurement mode (Sur: surface mode, bod: object mode, Cou: counting mode)

Fig. 8

Fig. 9

Fig. 10

Fig. 11

Fig. 12

Fig. 13

Infrared Thermometer User Guide

3.Install and replace battery

1

Remove three screws

2

Open the back base and install 18650 Li battery

TIP TEMPerature Products

340 W Broad Street, Burlington, NJ 08016
1-800-TIP-TEMP (847-8367)
[email protected]

4.Install method

1.Nail hook

3.Double-sided adhesive sticking

2.Bracket fixing

+

-

1.It is the user's responsibility to ensure the electromagnetic compatibility environment of

the device so that the device can work normally.

2.It is recommended to evaluate the electromagnetic environment before using the device.

3.When changing the operating environment, the device must be left to stand for more than 

30 minutes.

4.Please measure the forehead to the thermometer.

5.It is not recommended to use it outdoors or under strong light.

6.Keep away from air conditioners, fans, etc. 
7.Please use qualified, safety-certified batteries, unqualified batteries or non-rechargeable 

batteries used may cause fire or explosion.

8.If it cannot work after install the battery, please insert the charging cable to charge it and

it can be used normally.

5.Warnings

sku: TIPINF001