background image

                   

Installation/Operation

 

Manual

 

Pucada Tech

 

    ~ 23 ~                                  www.pucada.com 

 

h) Water Connection 

 

 

 

Warning: 

If the cold and hot connections to the heater are reversed, the heater will no 

function. Be certain there are no loose particles or dirt in the piping. Blow out or flush 

the lines before connecting to the water heater.   

 

Warning: 

Unions to be used as a point of disconnection to both water pipes to the inlet 

and outlet of the water heater. This will facilitate any necessary servicing.   

 

Warning: 

Do not use lead, PVC, iron or any piping which has been treated with 

chromates, boiler seal or other chemicals.   

 

Warning: 

No pressure reduction valve is required unless the water pressure exceeds 

1,000 kPa 

 

Warning: 

Do not fit any valves, restrictors or obstructions to the outlet of the water 

heater, or to the pressure relief located on the hot water outlet connection. 

 

  When water is required in one part of the system at a higher temperature than in the 

rest of the system, means such as a mixing valve shall be installed to temper the water 

to reduce the scald hazard.   

  Flush water through the pipe to clean out metal powder, sand and dirt before 

connecting it.   

  Prevent from using joints as many as possible to keep the piping simple. 

  Failure to supply the proper pressure to the unit may result in noisy operation, shorter 

life time of the unit, and may cause the unit to shut down frequently. 

 

Summary of Contents for AQUA28e Series

Page 1: ...3000 AS NZS 3500 4 wiring regulations and all Local Building Water and Gas fitting regulations This appliance must be installed and serviced by an authorized person responsible for 1 Give these instr...

Page 2: ...ion Models ECO30i AQUA28i P21i a Initial Power Up or Press Reset b Set up Time and Temperature Unit 35 c Operate the Water Heater 36 d Check Water Flow Rate 39 e Cleaning Water Filter Icon f Low Batte...

Page 3: ...s of the structure When such locations cannot be avoided it is recommended that a suitable drain pan adequately drained be installed under the appliance The pan must not restrict combustion air flow W...

Page 4: ...ontrol 2 C Gas valve control PCB designed and manufactured in house Digital electronic ignition LCD temperature control pad Error code system Module designed for easy maintenance Oxygen free copper he...

Page 5: ...UA28e GMS195OA Max 200 Min 13 5 Max 200 Min 13 5 Max 200 Min 13 5 P21e GMS150OA Max 160 Min 13 5 Max 160 Min 13 5 Max 160 Min 13 5 P21i GMS150IB Max 160 Min 13 5 Max 160 Min 13 5 Max 160 Min 13 5 Test...

Page 6: ...ector size mm Natural Gas 2 0 Propane ULP Gas 1 40 Electrical characteristic AC 230V 240V 50Hz 60Hz 0 32Amp for ECO30i ECO30e ECO24e AQUA28e AQUA28i 0 27Amp for P21i P21e Anti frost sensor 2 ON 10 OFF...

Page 7: ...ww pucada com 4 INSTALLATION a Included Accessories Part Image O ty Mounting Bracket 1 Hardware Kit 1 Installation Manual 1 Warning After installation the installer must test the appliance for correct...

Page 8: ...l flue 900mm length pipe TIT2 9088104 5 3 stainless steel coaxial flue elbow 90 TIT2 4588104 5 3 stainless steel coaxial flue elbow 45 TIT2 9266103 5 3 stainless steel condensation coaxial flue pipe T...

Page 9: ...Installation Operation Manual Pucada Tech 9 www pucada com c Dimensions Dimension ECO30i Series Dimension ECO30e ECO24e Series...

Page 10: ...Installation Operation Manual Pucada Tech 10 www pucada com Dimension AQUA28i Series Dimension AQUA28e Series...

Page 11: ...Installation Operation Manual Pucada Tech 11 www pucada com Dimension P21i Series Dimension P21e Series...

Page 12: ...ustible materials If the unit be installed in the vicinity of a permanent kitchen range or stove that has the possibility of generating steam that contains fats or oils use a dividing plate or other m...

Page 13: ...op of heater The location of the flue terminal must comply with the clearances show on this page If you are unsure about clearances not indicated here in general refer to S5601 or your local authority...

Page 14: ...ructure or obstruction facing a flue terminal 500 h From any other flue terminal cowl or combustion air intake 300 Horizontally from an open window door non mechanical air inlet or any other opening i...

Page 15: ...nt of the terminal to the opening may be deemed by the Technical Regulator to comply 2 See Clause 6 9 4 for restrictions on a flue terminal under a covered area 3 See Figure J3 for clearances required...

Page 16: ...egions of cold climate will create more condensation in the flue system The condensation collector should be used in cold climates Do not common vent or connect more than one appliance to this flue sy...

Page 17: ...f the pipe at the unit with all the effective length added to the outside wall Total horizontal vertical flue pipe length with the Number of 90 elbows 1 elbow 2 elbows 3 elbows 9 meters 8 meters 7 met...

Page 18: ...condensate trap should be used in cold climates If more than one elbow is used in the vertical section the condensate trap must be used Recommended condensation trap location The condensate trap must...

Page 19: ...ion please do not apply any unnecessary force to the unit while installing Action Attention Illustration Position mounting bracket 1 Open the mounting kit bag and take out the mounting bracket assembl...

Page 20: ...marked position a Then place the expansion bolt in the holes if it is brick or stone wall b Or then screw in wood screw in the hole if it is wooden wall Hang the unit again on the wall Recheck Ensure...

Page 21: ...building and length from the meter or regulator refer AS5601 Undersize the gas line may result in diminished hot water flow rate and temperature Proper gas pressure must be confirmed at time of instal...

Page 22: ...pipe sizing and details For gas outlet pressure adjustment it only can be done by authorized and certified installers For the adjustment details please refer to the Gas Outlet Pressure Adjustment Ins...

Page 23: ...cals Warning No pressure reduction valve is required unless the water pressure exceeds 1 000 kPa Warning Do not fit any valves restrictors or obstructions to the outlet of the water heater or to the p...

Page 24: ...removal of the water heater Pipe sizing from the cold water supply should be sized according to local BY LAWS for water supply When the appliance is used as a solar booster please ensure it does not r...

Page 25: ...for compliance with relevant parts of Australian and New Zealand gas electrical and water standards While Tinco Tech water heaters are warranted against defects the warranty is conditional upon correc...

Page 26: ...to the condensate outlet The end of this tube must be properly disposed to a sewer connection If the tube is blocked the water heater will shutdown When this occurs the tube must be removed to allow w...

Page 27: ...personnel or hand tools during the water installation and servicing to protect appliance s electronic control Warning Please always plug power lead wire into an earthed point to prevent electrical sho...

Page 28: ...Thermostatic temperature function inspection points 1 Press UP DOWN buttons 3 seconds to remove Child Key icon 2 Press UP or DOWN buttons to set up preferred temperature 3 Turn on the hot water faucet...

Page 29: ...x 158 x 38 5 5 Switching power 84 x 187 x 44 5 6 Mix water solenoid valve 66 5 x 72 5 x 32 7 LCD Display panel 65 5 x 140 x 17 5 8 Hot water Outlet connector 3 4 BSPT 9 Heat exchanger 208 x 350 x 135...

Page 30: ...x 72 5 x 32 6 LCD Display panel 65 5 x 140 x 17 5 7 Hot water Outlet connector 3 4 BSPT 8 Heat exchanger 208 x 350 x 135 9 Manifold 156 x 263 x 37 10 Control board 98 x 158 x 38 5 11 DC Brushless Blow...

Page 31: ...Mix water solenoid valve 66 5 x 72 5 x 32 6 LCD Display panel 65 5 x 140 x 17 5 7 Hot water Outlet connector 3 4 BSPT 8 Heat exchanger 208 x 350 x 135 9 Manifold 156 x 172 x 37 10 Control board 98 x...

Page 32: ...x 72 5 x 32 6 LCD Display panel 65 5 x 140 x 17 5 7 Hot water Outlet connector 3 4 BSPT 8 Heat exchanger 208 x 350 x 135 9 Manifold 156 x 172 x 37 10 Control board 98 x 158 x 38 5 11 DC Brushless Blo...

Page 33: ...x 140 x 17 5 8 Hot water Outlet connector 3 4 BSPT 9 Heat exchanger 208 x 350 x 135 10 Manifold 156 x 263 x 37 GMC195IB DC Brushless Blower 136 x 157 x 57 11 GMC195ID DC Brushless Blower 133 6x 152 2...

Page 34: ...er solenoid valve 66 5 x 72 5 x 32 7 LCD Display panel 65 5 x 140 x 17 5 8 Hot water Outlet connector 3 4 BSPT 9 Heat exchanger 208 x 350 x 135 10 Manifold 156 x 263 x 37 11 DC Brushless Blower 136 x...

Page 35: ...to change to PM Press the UP button and it will be changed back to AM 3 If there is no signal input within 10 seconds the system will turn into the default setup 12 00 AM Press DOWN button to PM press...

Page 36: ...to finish all setup Press MODE button to set up preferred temperature unit Press the DOWN or UP button to select or Press MODE button to finish all setup c Operate the Water Heater 1 The factory defau...

Page 37: ...locked and removed 6 Press UP or DOWN button to adjust the setup temperature The temperature adjustable range is from 36 97 to 48 118 for sanitary water use purpose Max 50 models 36 97 to 60 140 for n...

Page 38: ...er heater The LCD only show time AM12 00 Turn off the gas water heater 2 Press and hold OFF UP DOWN buttons When the DEMAND ENERGY icon starts flickering start turning into the High temperature Settin...

Page 39: ...ature The default temperature is 48 and the adjustable temperature range is from 49 120 52 126 IN USE SET TEMP icons flicker 6 If there is no signal input within 3 seconds the system will automaticall...

Page 40: ...e water filter may reduce the water flow rate from the tap or the shower and affect the performance of the water heater FILTER icon shown Must replace the water filter instantly Press and hold UP and...

Page 41: ...Temperature Unit Setting While plugging in the icon starts flicking 5 seconds Press button to switch to or press button to switch to b Turn On Gas Unit Press ON OFF button to turn the gas unit on and...

Page 42: ...mp 50 model d Remove Error Code Press MODE button for 3 seconds at least and the error code will be erased Then press ON OFF button to turn off and then ON OFF button to turn on the gas unit MODE e Re...

Page 43: ...le hearing 1 beep sound the high temperature setting function is activated Press each time to increase 1 Temperature setting range 48 75 g Setting Compensation Temperature Only for Max temp 50 model P...

Page 44: ...l Function Setting Table Function setting Setting status Setting method 1 Clean filter 2 Erase error code ON or OFF Press button 3 seconds Learning OFF Press buttons 3 seconds Temperature setting ON P...

Page 45: ...t Freezing will be prevented regardless of whether the operation switch is ON or OFF The freeze prevention heaters will automatically be switched on when the water temperature is less than 2 and be sw...

Page 46: ...te or fade the paint Use soft dry cloth to wipe cabinet b Flue System The flue system should be inspected at least annually for blockages or damage Keep the area around flue terminal free of snow and...

Page 47: ...scaling using a pump view the demonstration drawing below Disconnect electrical supply from the water heater Shut off the water supply to the water heater using installer supplied shutoff valve Open h...

Page 48: ...scard solution Position a container below the hot water outlet and connect cold water supply Open cold water supply isolation valve and flush heat exchanger with clean water Shut cold water shutoff va...

Page 49: ...is set too high To lower output temperature see operation of the control panel 2 Check water filter is not clogged 3 Make sure the unit is using the correct gas supplied 4 Mineral scale build up in t...

Page 50: ...the combustion chamber is sealed Leaky chamber may cause the system to operates erratically 2 Improper venting Venting that is unsealed or too long in run will result in unstable burner flames and no...

Page 51: ...valve wiring 9 Check valve outlet pressure 10 Replace gas valve I05 Ignition Flame off and re ignite fail over 5 times Shutdown Turn Off and Turn on Water 1 Check if gas type and pressure is correct...

Page 52: ...age during water heater in use Shutdown Turn Off and Turn on Water 1 Check flue terminal for blockage and remove blockage P01 No feedback of pressure sensor Lock out Press and hold Off and Reset for m...

Page 53: ...t Replace control box C06 MCU MUX error Shutdown Auto Reset Replace control box C07 MCU Clock error Shutdown Auto Reset Replace control box C08 Cap failure Shutdown Auto Reset 1 Check the cap if insta...

Page 54: ...er than factory setting Warning Turn Off and Turn on Water 1 Check if gas type and pressure is correct 2 NTC oxidized 3 Replace water flow sensor 4 Rinse and clean heat exchanger H02 Heat Exchanger Ef...

Page 55: ...l Pucada Tech 55 www pucada com 10 ELECTRICAL WIRING DIAGRAM Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify prop...

Page 56: ...parking F03 Block flue during pre purge F02 Blower Aging I02 Flame Error I03 Re ignite Overtime YES I04 Ignition fail I05 Re ignite Fail Error NO Error NO 4 User Setting 5 Water flow Temp rise conditi...

Page 57: ...ers any defects in materials when the product is installed and operated according to Tinco Tech written installation instructions subject to the terms within this Limited Warranty document Improper in...

Page 58: ...et applicable building codes ordinances or normal plumbing and electrical trade practices Damages malfunctions or failures resulting from improper installation of the water header or failure to operat...

Page 59: ...emically treated water such as for swimming pools or spas This water heater is suitable for filling large or whirlpool tubs with potable water Refer to the Water Quality section in the Operation and I...

Reviews: