background image

 

User Manual-TA2P 

 

 

 

Version C May 2020 

20  of  21 

20 

 

 

Ordering key 

3.2

*Please contact your TiMOTION sales engineer for the latest revision ordering key. 

 

 

Summary of Contents for TA2P

Page 1: ...User Manual TA2P Version C May 2020 1 of 21 A User Manual TA2P...

Page 2: ...Cable 9 2 2 3 Inrush current 10 Wiring definitions 11 2 3 2 3 1 Limitations for limit switches output signals 11 2 3 2 Two limit switches to cut the current without signal output 12 2 3 3 Two limit sw...

Page 3: ...stroke Low LS Lower limit switch is installed in fully retracted end of stroke Mid LS Middle limit switch is installed and the position is set by customer s request N C It is the pin of limit switch w...

Page 4: ...get Personnel 1 2 Please allow qualified mechanical and electrical professionals perform all installation maintenance and replacement of the TiMOTION products Please keep the products away from people...

Page 5: ...nt that the actuator is or shall be a part of Adhere to the information contained in this user manual and on the product label Never exceed the performance limits stated herein Be sure the actuator is...

Page 6: ...here is no side load present on the actuator Only use the actuator within the specified working limits Refrain from having any contact with the actuator 1 8 3 Equipment power off Switch off the main s...

Page 7: ...threaded at both ends of the attachments Do not mount the actuator with the pins in different rotated angles this could cause stress on the nut during operation The load should act along the stroke ax...

Page 8: ...ease ensure it is able to withstand the peak of high voltage To reduce the chance of interference refrain from placing signal cables along power cables Use a two wire system to prevent ground loop Ple...

Page 9: ...wer cable 20AWG 2 2 2 Cable The actuator is supplied with a power cable and or signal cable The standard cable for industrial applications has have flying leads in the end for the user s equipment con...

Page 10: ...or starts to work there is an inrush current to the motor that will be less than 0 2 seconds up to four times the rated current Please select a power supply that is able to withstand the inrush curren...

Page 11: ...function limitations for limit switches to output signals are shown in the table below Functions for limit switches Signal output Without POT Single Hall Double Hall 2 limit switches to cut the curre...

Page 12: ...nt of the motor when the actuator moves to the end of each stroke and without any output signal Wire AWG Description Spec Yellow 20 Connect to Vm to extend the actuator Connect to Vm to retract the ac...

Page 13: ...Input voltage 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator White 26 Connect to common pin C The signal is potentia...

Page 14: ...nput voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator Red 26 Connect to common pin C The signal NOT potential free actively outputs voltage at the...

Page 15: ...m to retract the actuator 24V version Input voltage 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator Red 26 Connect to...

Page 16: ...ct to Vm to retract the actuator 24V version Input voltage 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator Red 26 5V...

Page 17: ...ge 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator Red 26 5V DC input signal power for Hall sensor board Hall sensor...

Page 18: ...or 24V version Input voltage 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator White 26 POT signal ground POT output si...

Page 19: ...User Manual TA2P Version C May 2020 19 of 21 3 Product specifications 2D drawings 3 1 With POT or Reed Sensor Without sensor or with Hall sensors...

Page 20: ...User Manual TA2P Version C May 2020 20 of 21 Ordering key 3 2 Please contact your TiMOTION sales engineer for the latest revision ordering key...

Page 21: ...the external control unit Customer fuse burned Check the fuse Cable damaged Please contact your TiMOTION sales engineer Excessive power consumption Misalignment or overload in the application Align o...

Reviews: