User Manual-MA1_DC Version
Version B July 2020
14 of 24
14
2.3.3
Two limit switches to send signal
The actuator is equipped with two limit switches to send signal when the actuator moves to the end of each
stroke
.
Wire
AWG
Description
Spec
Red
(Power)
14
Connect to Vm+ to extend the actuator
Connect to Vm- to retract the actuator
24V version: Input voltage 18~32 V DC
12V version: Input voltage 9~16 V DC
Black
(Power)
14
Connect to Vm- to extend the actuator
Connect to Vm+ to retract the actuator
Yellow
(Signal)
18
Connect to common pin (C.)
The signal is potential free and independent
from the motor power circuit.
The signal is short circuit when the actuator
moves to the position where the middle
limit switch is triggered.
Connect the middle limit switch signal with
max 32V, <1A.
Green
(Signal)
18
Connect to normal closed pin (N.C.)
Red
(Signal)
18
Connect to normal closed pin (N.C.)
Black
(Signal)
18
Connect to common pin (C.)
Red (Power)
Black (Power)
Yellow (Signal)
Green (Signal)
Red (Signal)
Black (Signal)