background image

 

Page 1

 

73J037 REV. A 

 

PROM Installation Guide 

Micro Lynx VITC Option Card 

TIMELINE VISTA, INC. 

1755 LA COSTA MEADOWS DRIVE, SUITE B 

SAN MARCOS, CA  92069 

TEL. 760-727-3300 

(FAX 760-727-3620) 

[email protected]

 

DATE:

 

08/13/93

 

MODEL:

 

Micro Lynx

 

REVISION:

 

All

 

SERIAL NO:

  All

 

SOFTWARE:

  All

 

REQUIRED TOOLS: 

Static safe workstation 

IC Extractor/Insertor or 

Grounding wrist strap 

small slotted screwdriver 

Phillips screwdriver 

REQUIRED PARTS: 

Replacement PROM from TimeLine 

PROCEDURE: 

1.  Turn off the power to the System Unit.  

Disconnect all cables. 

2.  Place the Micro Lynx System Unit on a 

static safe workstation.  Ground yourself 
and the workstation anti-static mat. 

3.  Remove the six phillips screws holding 

the top cover to the chassis and remove 
the cover.  (See Figure 1) 

 

Figure 1.  Remove the Top Cover 

4.  Disconnect the option card ribbon cable from J3 on the Main Board, and J1 on the VITC 

Card.   

5.  Locate U5, the VITC PROM.  Remove and replace the PROM.  Be careful to correctly align 

Pin 1 and properly seat the PROM.  See Figure 2.   

 

Warning

 

 

Use an IC insertor to remove and replace the PROM.  If one is not available, use a small slotted 

screwdriver.  Insert the screwdriver between the PROM and the socket, twist slightly  and gently lift up.  

Inserting the screwdriver incorrectly could damage surrounding components. 

 

Reviews: