May-10
Page 1
73J011 REV A
PROM Installation Guide
Micro Lynx ACG Option Card
q
Optional
TIMELINE VISTA, INC.
1755 LA COSTA MEADOWS DRIVE, SUITE B
q
Recommended
SAN MARCOS, CA 92069
TEL. 760-761-4440
q
3
Mandatory
(FAX 760-761-4449)
DATE:
04/22/92
MODEL:
Micro Lynx
REVISION:
All
SERIAL NO:
All
SOFTWARE:
ACG PROM
U12
REQUIRED TOOLS:
Static safe workstation
IC Extractor/Insertor or
Grounding wrist strap
small slotted screwdriver
Phillips screwdriver
REQUIRED PARTS:
Software Information Sheet
Replacement PROM from TimeLine
PROCEDURE:
1. Turn off the power to the System Unit.
Disconnect all cables.
2. Place the Micro Lynx System Unit on a
static safe workstation. Ground yourself
and the workstation anti-static mat.
3. Remove the six phillips screws holding
the top cover to the chassis. Remove the
top cover.
4. Remove the two phillips screws securing
the ACG Card to the bracket. Disconnect
the option card cable from the main board
and the M3 Option Card, if installed. Slide
the ACG Card foward until the connectors
clear the back panel and place on a static
safe workstation component side up.
Figure 1. Remove the Top Cover