5. Installation

• Ensure the mains supply is switched off and the circuit supply fuses  

are removed or the circuit breaker turned off.

• This product is designed to be mounted on walls or under eaves  

(See diagram “C”). The sensor can be rotated through 180 degrees  
to direct detection where required.

• An isolating switch should be installed to enable the power to be switched ON 

and OFF for maintenance purposes and to activate the manual/auto  
override function. 

• Unscrew the wiring box fixing (See diagram “D”). This screw is captive,  

do not fully remove.

• Detach the wiring box by gently pulling it away from the PIR sensor body.

• Mark the position of the fitting holes using the wall plate as a template. Drill 

out the mounting holes taking care to avoid any joists, electrical cables or 
water/gas pipes that may be hidden beneath the surface. Insert the rawl plugs 
into the holes.

• Pass the cables through the cable entry points on the wiring box, ensuring the 

grommet(s) is used to maintain the IP rating of the PIR sensor.

• Fix the wall plate to the wall using the correct screws for the rawl plugs 

installed (See diagram “E”).

• This unit features an installation aid. Simply hang the PIR sensor onto the  

wall plate by use of the clip arrangement on the wall plate (See diagram “F”). 
This allows you to use your hands to hold the screwdriver, and install the 
incoming cables with ease.

• Terminate the cables into the terminal block ensuring correct polarity is 

observed and that all bare conductors are sleeved (See section 6.  
Connection Diagram).

• Ensure the connections are secure, and that the terminal blocks are attached  

to the mounting posts in the PIR sensor body.

• Un-hook the sensor unit and re-attach to the wiring box, ensuring none  

of the wires are trapped.

• Align the PIR sensor centrally over the wiring box, and attach the top edge of 

Summary of Contents for MTLW3000

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 2300W PIR Light Controller Model MTLW3000 White...

Page 2: ...the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50 Hz This PIR is of Class ll Construction and must not be earthed Motion Detection Range Up to 12 metres at...

Page 3: ...ll not detect through glass e g in a glazed porch The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS See diagram B Therefore position the unit so tha...

Page 4: ...en beneath the surface Insert the rawl plugs into the holes Pass the cables through the cable entry points on the wiring box ensuring the grommet s is used to maintain the IP rating of the PIR sensor...

Page 5: ...e in place Slowly rotate the PIR sensor body downwards and back upwards to double check that no wires are trapped Fully tighten the fixing screw See diagram D Diagram C Diagram E Diagram G Diagram F D...

Page 6: ...lluminate for approximately 1 minute This indicates the unit is wired correctly and the unit is in Test Mode Adjust the sensor head to the desired direction for best coverage See diagram C Note Anglin...

Page 7: ...te Repeat the above walking at various angles and distances to the unit This will help you to establish the detection pattern If the detection area is too small for your requirements try angling the s...

Page 8: ...ximately the same level of darkness each evening Observe the operation of the unit If the unit is starting to operate too early i e when it is quite light adjust the control slightly anti clockwise If...

Page 9: ...andom Solution The unit may be suffering from false activation Cover the sensor lens completely with a thick cloth This will prevent the sensor from seeing anything If the unit now switches off after...

Page 10: ...that the unit will not detect through glass e g in a glazed porch The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness...

Page 11: ...proof of purchase and it will be replaced free of charge For years 2 and 5 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all case...

Page 12: ...il csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppo...