background image

Ins
tallation & Oper

ating Ins

tructions

1

LED Wide Beam  

PIR Floodlight

Model: LEDX10PIRBN (Black) 

Model: LEDX10PIRWHN (White)

Model: LEDX20PIRBN (Black) 

Model: LEDX20PIRWHN (White)

Model: LEDX30PIRBN (Black) 

Model: LEDX30PIRWHN (White)

Summary of Contents for LEDX10PIRBN

Page 1: ...n O p e r a t i n g I n s t r u c t i o n s LED Wide Beam PIR Floodlight Model LEDX10PIRBN Black Model LEDX10PIRWHN White Model LEDX20PIRBN Black Model LEDX20PIRWHN White Model LEDX30PIRBN Black Mode...

Page 2: ...otal load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50Hz These luminaires are of...

Page 3: ...r to turn ON all the lights connected 4 Installation Advice As the detector responds to changes in temperature avoid the following situations Pointing the detector towards objects with highly reflecti...

Page 4: ...e of about 180 5 Installation Procedure 5 1 Mark the position of the mounting holes on the wall using the U bracket supplied as a template 5 2 Drill the holes for the wall plugs ensuring not to infrin...

Page 5: ...d 5 7 Attach the supplied wall plate to the luminaire apply pressure to catches located on top and bottom until all click into place to ensure the weatherproof seal 5 8 Attach the luminaire to the U b...

Page 6: ...LIVE Brown or Red L NEUTRAL Blue or Black N EARTH Green Yellow Connect the 3 core mains supply cable to the terminal block on the unit as follows LIVE Brown or Red L1 NEUTRAL Blue or Black N EARTH Gre...

Page 7: ...t Procedure Adjust the Time knob to fully anti clockwise and Lux knob can be set to Sun or Moon Switch the power On Walk across the detection area once to detector is triggered the lamp will turn ON f...

Page 8: ...b setting You can set the time knob from 5 seconds to about 10 minutes the floodlight will switch the lamp ON for the time duration set after each detected movement Adjust the knob as desired LUX knob...

Page 9: ...9 Lens Masking The purpose of the lens mask is to mask out areas not desired for detection Masking the Sensor Lens To restrict the sensor coverage preventing detection in unwanted areas mask the senso...

Page 10: ...nds The unit will now illuminate continuously until dawn or until switched back into Auto Mode To switch the unit back into Auto Mode switch the internal wall switch circuit breaker once OFF ON within...

Page 11: ...y activate the sensor Sometimes passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to allow detection of cars people using public thoroughfares adjac...

Page 12: ...n light output Tilt the PIR sensor further downwards and away from the floodlight Once the floodlight has settled into the new time settings re angle the PIR sensor back to your desired position Unit...

Page 13: ...proof of purchase and it will be replaced free of charge For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all case...

Page 14: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppor...

Reviews: