INST
ALLA
TION
& O
per
A
TIN
g
ruc
TIONS
500W multi Pir
Halogen floodligHt
cat No. MLB500c - Black
cat No. MLW500c - White
150W multi Pir
cat No. MLB150c - Black
cat No. MLW150c - White
installation & operating
instructions
Page 1: ...N o p e r atin g inst r u c tions 500W multi Pir Halogen floodlight Cat No MLB500C Black Cat No MLW500C White 150W multi Pir Halogen floodlight Cat No MLB150C Black Cat No MLW150C White Installation O...
Page 2: ...tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body...
Page 3: ...screws to prevent damage to the mounting plate If using a power screwdriver use the lowest torque setting IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switchin...
Page 4: ...Place this edge against walland use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length NOT TO SCALE...
Page 5: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Holiday Mode Time...
Page 6: ...are factory set Lux is set to the moon setting and Time is set to a minimum fully anti clockwise see diagram G Turn the power to the unit on The lamp will illuminate for approximately 30 seconds This...
Page 7: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...
Page 8: ...quired See diagram G the adjustment knob is identified by the letter T inside a circle Do not adjust this setting if you do not wish to use the Holiday Mode facility This time adjustment is factory se...
Page 9: ...the procedure below See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols Set the DUSK control knob fully anti clockwise Wait until darkness falls When the ambient light leve...
Page 10: ...only when motion is detected Automatic Mode is indicated by scrolling LEDs from Left to right You may not be allowing the unit time to complete it s warm up period Stand well out of the detection ran...
Page 11: ...the current DUSK setting During daylight adjust the DUSK control slightly anti clockwise When the lamp load extinguishes enter the detection area If the PIR still activates the setting is still too hi...
Page 12: ...ne timeguard com For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com A Group company For assistance with the p...