background image

 
IM2021

 

40 

 

 

13.  UTILIZATION RULES 

 

After  the  lifetime  of  the  device  expires,  it  should  be  recycled  in  compliance  with  the 
laws, rules and methods in region of recycling. Detailed information about the recycling 
of  the  device,  you  can  receive  from  a  representative  of  the  local  authorities,  after 
providing  full  information  about  the  device.  The  manufacturer  and  authorized 
organization  of  the  manufacturer  do  not  carry  responsibility  for  the  fulfillment  by  the 
Buyer of the requirements of legislation on utilization and methods of utilization of the 
device  selected  by  the  Buyer.  The  lifetime  of  the  device  is  indicated  in  the  warranty 
card. Warranty period for the device  and  warranty  terms are specified in the  warranty 
card. The warranty card is an integral part of the documentation supplied with this unit. 
If there is no warranty card in the delivery set, ask for it from the Seller. The warranty 
card provided by the Seller must conform to the manufacturer’s form. 
The  manufacturer  and  the  authorized  organization  of  the  manufacturer  remove 
responsibility  for  any  possible  harm  which  can  be  caused  to  people,  animals  or 
property  directly  or  indirectly,  if  this  harm  occurred  as  a  result  of  noncompliance  with 

The cooling 
effect is not 
good 

Doors or windows are open; 
there are a lot of people; or in 
cooling mode, there are other 
sources of heat.  

Close doors and windows, and add 
new air conditioning.  

The filter screen is dirty.  

Clean or replace the filter screen.  

The air inlet or outlet is 
blocked.  

Clear obstructions.  

Big Noise 

The air conditioning is not 
placed on a flat surface.  

Put the air conditioning on a flat and 
hard place (to reduce noise). 

compressor 
does not 
work.  

Overheat protection starts.  

Wait for 3 minutes until the 
temperature is lowered, and then 
restart the machine. 

The remote 
control does 
not work. 

The distance between the 
machine and the remote 
control is too far. 

Let the remote control get close to 
the air conditioning, and make sure 
that the remote control directly faces 
to the direction of the remote control 
receiver. 

The remote control is not 
aligned with the direction of the 
remote control receiver. 
Batteries are dead.  

Replace batteries.  

Displays 'E1' 

The room temperature 
indicator is abnormal. 

Check the room temperature 
indicator. Disconnection of contact 
assemblies is possible. 

Displays 'E2' 

The pipe room temperature is 
abnormal. 

Check  the  pipe  temperature  sensor. 
Possible  failure,  replacement  is 
required. 
 

Summary of Contents for T-PAC12-P11E

Page 1: ...INSTRUCTION MANUAL RU 2 EN PORTABLE TYPE ELECTRIC AIR CONDITIONER 22 KZ 42 T PAC12 P11E...

Page 2: ...IM2021 2 1 2...

Page 3: ...IM2021 3 2 0 C 2 17 35...

Page 4: ...IM2021 4 3 5 10A 8 R290 12 2...

Page 5: ...IM2021 5 3 4 1 1 2 3 4 5 6 7 8...

Page 6: ...IM2021 6 9 10 11 12 13 14 15 16 17 5 1 1 2 1 3 1 4 1 5 1 6 1 7 1 6 T PAC12 P11E BTU 12000 3530 1357 220 240 50 5 9 3 400 0 8 55 65 R290 0 99 Class I...

Page 7: ...IM2021 7 230 15 35 2 18 26 1134 Ruizhi 3 0 6 1 8 27 30 7 420 360 720 477 397 875 7 2 1 1 2 2...

Page 8: ...IM2021 8 1 2 2 1 2 1 3 4 2 3 4 3 4 1 4 1 50 5 5...

Page 9: ...IM2021 9 2 6 7 6 7 280 1500 8 1 2 Power 3 Mode 4 Up Down...

Page 10: ...IM2021 10 5 Fan 6 Timer 1 24 1 7 Sleep Up Sleep...

Page 11: ...IM2021 11 1 2 FULL 9 4 9 1 2 1 12 3 1 2 4...

Page 12: ...IM2021 12 8 1 2 3 9 1...

Page 13: ...IM2021 13 2 3 10 40 1...

Page 14: ...IM2021 14 2 3 4 5 10 1 2 3 4 5 CO 2...

Page 15: ...IM2021 15 6 7 8 9...

Page 16: ...IM2021 16 10 11 12 13...

Page 17: ...IM2021 17 14 OFN 15 OFN OFN OFN...

Page 18: ...IM2021 18 16 OFN 17 a b c d e f g 80 h i j 18...

Page 19: ...IM2021 19 19 11...

Page 20: ...IM2021 20 12 7 35 17 3...

Page 21: ...IM2021 21 13 14 1 2 30 C 50 C 15 85 5 E1 E2...

Page 22: ...their property Read these instructions carefully before using the appliance to avoid damage during use Before starting up for the first time check that the specifications on the product comply with t...

Page 23: ...store gasoline or other volatile flammable liquids near the air conditioner this is very dangerous Use the device to cool the air at an ambient temperature of 17 35 C Clean the filters periodically to...

Page 24: ...a room with an area of more than 12 m2 Store the device in a well ventilated place The non ventilated area where the device is installed shall be arranged in such a way that in case of cooling agent...

Page 25: ...differ from the images in the manual 1 Top cover 2 Control panel 3 Handle 4 Front side body 5 Rollers 6 Air filter 7 The opening for the drain hose for utomatic condensate removal 8 Handle 9 The open...

Page 26: ...the device are indicated in table Parameter Units T PAC12 P11E Capacity cooling BTU kW 12000 3530 Rated power consumption cooling W 1357 Power supply V Hz 220 240 50 Rated power current cooling 5 9 A...

Page 27: ...875 7 DEVICE INSTALLATION Warning before using the mobile air conditioning keep it upright for at least two hours The air conditioning can be easily moved in the room In the moving process ensure that...

Page 28: ...rection 2 Pull various components of the window sealing plate assembly open adjust their opening distance to bring both ends of the assembly into contact with the window frame and fix various componen...

Page 29: ...Do not use extension tubes or replace it with other different hoses or this may cause a malfunction Exhaust host must be not blocked otherwise it may cause overheating 8 DEVICE CONTROL Control panel 1...

Page 30: ...n 6 Timer In the case of power on press the key to close timing in the case of power off press the key to open timing Press the key when the timing symbol flashes press up and down key to select the r...

Page 31: ...function The machine has automatic defrosting function Defrosting can be achieved through four way valve reversing 4 Protection Function of the Compressor To increase the service life of the compresso...

Page 32: ...condensation from spilling onto the floor Fig 8 Automatic condensate removal optional only works in DRY mode 1 Unscrew the drain cap and remove the water plug 2 Install the drain hose into the drain...

Page 33: ...rm water with a mild detergent with a temperature of about 40 C rinse it and remove any dirt Before installing the filter in the air conditioner it is necessary to dry it avoiding direct sunlight Air...

Page 34: ...d with prior to conducting work on the system 2 Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work...

Page 35: ...hin which the refrigerant containing parts are installed The ventilation machinery and outlets are operating adequately and are not obstructed If an indirect refrigerating circuit is being used the se...

Page 36: ...the manufacturer Other parts may ignite the cooling agent in the atmosphere due to its leakage 12 Wiring Make sure the cables are not exposed to wear corrosion overpressure vibration damage due to co...

Page 37: ...near sources of ignition and that there is ventilation 16 Cooling agent recharging procedure The following requirements shall be met in addition to the regular charging procedures Ensure the absence o...

Page 38: ...the total system charge Make sure that all the used cylinders are designed for the extracted cooling agent and have the marking appropriate for this type of cooling agent i e special cylinders for th...

Page 39: ...with electricity The overflow indicator displays FL Discharge the water inside The ambient temperature is too low or too high Recommend to use the machine in at the temperature of 7 35 44 95 In coolin...

Page 40: ...als or property directly or indirectly if this harm occurred as a result of noncompliance with The cooling effect is not good Doors or windows are open there are a lot of people or in cooling mode the...

Page 41: ...rting and storage should be provided in strict accordance to the manipulation marks 3 Outdoor unit should be transported vertical Temperature Requirements Transportation and storage From 30 C up to 50...

Page 42: ...IM2021 42 1 2 2...

Page 43: ...IM2021 43 17 35 3 5 10 R290 12 2...

Page 44: ...IM2021 44 3 4 1...

Page 45: ...IM2021 45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 FULL 5 1 1 2 1 3 1 4 1 5 1 6 1 7 1 6 T PAC12 P11E BTU 12000 3530 1357 220 240 50 5 9 3 400 0 8 55 65 R290...

Page 46: ...IM2021 46 0 99 Class I 230 15 35 2 18 26 1134 Ruizhi 3 0 6 1 8 27 30 7 420 360 720 477 397 875 7 2 1 2 2...

Page 47: ...IM2021 47 2 1 2 2 1 2 1 3 4 2 3 4 3 4...

Page 48: ...IM2021 48 1 4 1 50 5 5 2 6 7 6 7 280 1500...

Page 49: ...IM2021 49 8 1 2 Power 3 Mode 4 Up Down 5 Fan 6 Timer 1 24 1 7 Sleep Up...

Page 50: ...IM2021 50 1 2 FULL 3 4...

Page 51: ...IM2021 51 9 1 2 3 1 2 4...

Page 52: ...IM2021 52 8 1 2 3 9 1 2 3...

Page 53: ...IM2021 53 10 40 C 1 2 3 4 5...

Page 54: ...IM2021 54 10 1 2 3 4 5 CO 2 6...

Page 55: ...IM2021 55 7 8 9 10...

Page 56: ...IM2021 56 11 12 13 14...

Page 57: ...IM2021 57 OFN 15 OFN OFN OFN 16 OFN 17...

Page 58: ...IM2021 58 a b c d e f g 80 h i j 18 19...

Page 59: ...IM2021 59 11 12...

Page 60: ...IM2021 60 7 35 C 17 C 3 E1 E2...

Page 61: ...IM2021 61 13 14 1 2 30 C 50 C 15 85 5...

Page 62: ...IM2021 62...

Page 63: ......

Page 64: ...www timberk ru...

Reviews: