8
Gross
weight
(outdoor unit)
kg
23
24.5
30
39
49
Net
dimensions
(indoor unit)
mm
693*250*190
700*290*190
800*290*190
900×310×225
950×320×230
Net
dimensions
(outdoor unit)
mm
670*254*430
670*254*430
720*255*520
800*290*530
800*290*530
Packing dimensions
(indoor unit)
mm
770*320*285
780*375*285
875*375*285
955×380×290
1035×395×315
Packing dimensions
(outdoor unit)
mm
778*342*500
778*342*500
835*360*605
905*400*630
905*400*630
8. INSTALLATION OF THE DEVICE
Important Notices:
Before installing, please contact with local authorized maintenance center, if unit is not
installed by the authorized maintenance center, the malfunction may not be solved, due to
discommodious contact. To move and install air conditioner to another place, also please
contact our local special service center.
The air conditioner must be installed by professionals according to the national wiring rules
and this manual.
Requirements for Installation position:
Avoid places of inflammable or explosive gas leakage or where there are strongly
aggressive gases.
Avoid places subject to strong artificial electric/magnetic fields.
Avoid places subject to noise and resonance.
Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct sunshine
or high temperature heat sources).
Avoid places within the reach of children.
Select where it is easy to perform service and repair and where the ventilation good.
The outdoor unit shall not be installed in any way that could occupy an aisle, stairway, exit,
fire escape, catwalk or any other public area.
The outdoor unit shall be installed as far as possible from the doors and windows of the
neighbors as well as the green plants.
Requirements of the mounting structure:
The mounting rack must meet the relevant national or industrial standards in terms of
strength with welding and connection areas rustproofed.
The mounting rack and its load carry surface shall be able to withstand 4 times or above
the weight of the unit.
The mounting rack of the outdoor unit shall be fastened with expansion bolt.
Ensure the secure installation regardless of what type of wall on which it is installed, to
prevent potential dropping that could hurt people.
Electrical Safety Requirements:
Be sure to use the rated voltage and air conditioners dedicated circuit for the power supply,
and the power cable diameter must meet the national requirements.