background image

 

 
 
 
 
 
 

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ 
INSTRUCTION MANUAL 

 
 
 
 
 

RU 

ТЕПЛОВЕНТИЛЯТОР ЭЛЕКТРИЧЕСКИЙ СТАЦИОНАРНЫЙ (ТЕПЛОВАЯ ЗАВЕСА)

 ............. 2 

 

ENG 

AIR CURTAIN

 .............................................................................................. 18 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Модели/Models: 

 

THC WT1 3M 
THC WT1 5M 
THC WT1 6M 
THC WT1 9M 
THC WT1 12M 
THC WT1 18M 
THC WT1 24M 

Summary of Contents for Power Door Series

Page 1: ...INSTRUCTION MANUAL RU 2 ENG AIR CURTAIN 18 Models THC WT1 3M THC WT1 5M THC WT1 6M THC WT1 9M THC WT1 12M THC WT1 18M THC WT1 24M...

Page 2: ...IM2020 2 1 2 1 2 3 4 5 6...

Page 3: ...IM2020 3 7 8 9 10 11 12 13 0 C 2 14 15 16 17 18 19 20 21 22 23 24 25 26 3 27 28 29 30 31 32 93...

Page 4: ...WT1 12M THC WT1 18M THC WT1 24M 220 50 220 50 380 50 380 50 380 50 380 50 380 50 13 7 20 5 9 1 13 7 18 5 27 5 36 4 3000 4500 6000 9000 12000 18000 24000 0 1500 3000 0 2250 4500 0 3000 6000 0 4500 9000...

Page 5: ...910 1610 1910 6 5 10 16 21 32 32 32 145 180 820 215 230 800 215 230 1060 215 230 1420 215 230 1910 215 230 1910 215 230 1910 1 2 1 2 A B C D H G L THC WT1 3M 35 760 20 150 215 840 THC WT1 5M 52 680 46...

Page 6: ...IM2020 6 5 2 1 2 3 4 THC WT1 3M THC WT1 5M 5 THC WT1 6M THC WT1 9M THC WT1 12M THC WT1 18M THC WT1 24M 1 O 2 3 6 1 1 2 1 3 1 4 1...

Page 7: ...IM2020 7 7 1 2 2 2 1 5 3 WT1 3M 4 50 5 6 7 9 12 2 1 2 1000 3 THC WT1 3M THC WT1 5M 1 220 198 242 2 3 1 16 1 5 2 2 5 2...

Page 8: ...THC WT1 6M THC WT1 9M 1 380 342 418 2 3 1 1 5 2 2 16 THC WT1 12M THC WT1 18M THC WT1 24M 1 380 342 418 2 3 40 4 THC WT1 12M 2 5 2 THC WT1 18M 4 0 2 THC WT1 24M 6 0 2 5 25 THC WT1 12M 32 THC WT1 18M 40...

Page 9: ...IM2020 9 8 THC W 1 3M THC WT1 5M 3 1 2 THC WT1 3M THC WT1 5M 1 1 1 0 1 2 1 3 2 2 2 2 1...

Page 10: ...IM2020 10 2 2 10 20 3 4 3...

Page 11: ...IM2020 11 THC WT1 6M THC WT1 9M THC WT1 12M THC WT1 18M THC WT1 24M 4 1 2 I II 3 THC WT1 6M THC WT1 9M THC WT1 12M THC WT1 18M THC WT1 24M 1 1 1 OFF 1 2 1 3 ON 2 II...

Page 12: ...IM2020 12 2 2 1 I 2 2 II 10 20 3 3 1 5 30 3 2 3 3 4 5 3 OFF 9...

Page 13: ...IM2020 13 10 3 3...

Page 14: ...IM2020 14...

Page 15: ...IM2020 15 11 THC W 1 3M 5 1 EK2 1 M2 SA1 SA2 SK1 SK2 1 XT1 THC W 1 5M 6...

Page 16: ...IM2020 16 1 2 1 1 SA1 SA2 SK1 SK2 THC W 1 6M THC W 1 9 7 A1 C1 EK1 EK6 KM1 KM2 1 SK1 SK2 SK3 XT1 XT2...

Page 17: ...IM2020 17 THC WT1 12M THC WT1 18M THC WT1 24M 8 A1 C1 EK1 EK6 KM1 KM2 1 SK1 SK2 SK3 XT1 XT2 12...

Page 18: ...some misprints in text and digital notations in the present manual IMPORTANT Important safeguards and descriptions contained in this manual do not include all possible situations that you may experien...

Page 19: ...not pull on the power cord grasp the plug Do not twist and do not wind it on anything 17 The curtain should always be monitored its long term operation without qualified personnel is prohibited 18 Nev...

Page 20: ...room to maintain a comfortable temperature in installation zone of the curtain Also with the heating elements turned off it can be used in summer to protect the air conditioned room from penetrating...

Page 21: ...10 Net weight kg 6 5 10 16 21 32 32 32 Device dimensions mm 145 180 820 215 230 800 215 230 1060 215 230 1420 215 230 1910 215 230 1910 215 230 1910 Dimensional characteristics Dimensional characteris...

Page 22: ...of sheet steel coated with a high quality polymer coating finned tubular heating element and fan unit Fans take air through the perforated grille 2 after which the air flow passing through the heating...

Page 23: ...cialists in accordance with Rules for the installation of electrical devices and Safety Rules for the operation of electrical devices operating at voltages up to 1000V 3 Before connecting the curtain...

Page 24: ...ctory To do this it is necessary to unscrew the screw on the control panel remove the top cover and remote control panel mount the remote control on the wall Install the panel and the top cover instru...

Page 25: ...on and the indicator of the second button will light up ATTENTION The first time the curtain is turned on a specific odor and smoke may appear oil is burned from the surface of the heating elements It...

Page 26: ...t the heating power mode switch to II ATTENTION The first time the curtain is turned on a specific odor and smoke may appear oil is burned from the surface of the heating elements It is recommended to...

Page 27: ...r Malfunction Possible cause Solution The device is connected to the network but doesn t work No power Check whether the power supply is disconnected from the device and if necessary connect device to...

Page 28: ...ontact an authorized service center The air flow speed has decreased the outside air easily gets into the room Malfunction in circuit breaker Change the circuit breaker Perforated air intake grille is...

Page 29: ...IM2020 29 THC W 1 5M Fig 6 1 2 heating elements 1 magnetic switch 1 fan motor SA1 network switch SA2 heating power mode switch SK1 SK2 thermal limiters THC W 1 6M THC W 1 9 Fig 7...

Page 30: ...ulfillment by the Buyer of the requirements of legislation on utilization and methods of utilization of the device selected by the Buyer The lifetime of the device is indicated in the warranty card Wa...

Page 31: ...marks Temperature Requirements Transportation and storage From 30 C up to 50 C Humidity Requirements From 15 up to 85 without condensate We are exploring new technologies and we constantly improving...

Page 32: ...www timberk ru...

Reviews: