CONTENTS

1. Information
2. Precautions
3. Technical characteristics
4. Description of portable air conditioner
5. Control of portable air conditioner

    Control panel for remote control
6. Maintenance
7. Service life
8. Rules of disposal
9. Helpful advice
10. Troubleshooting

2

www.timberk.com

   

electric floor standing air  onditioner  ortable type (single case) 

1. IMPORTANT INFORMATION

1.  Please  read  this  instruction  manual  carefully  prior  to  installation  and 

operation of a portable air conditioner.
2.  To  avoid  damage  to  the  air  conditioner  and  voiding  your  guarantee, 

before start using the air conditioner put the device in a vertical position (as 

shown on the cover of this instruction manual) for at least 2 hours prior to 

operation.
3. There may be misprints in the text and digital symbols in this manual.
4.  If  after  reading  the  manual  you  would  still  have  questions  regarding 

functioning  and  operation  of  the  device,  please  contact  the  seller  or  a 

specialized service center for clarifications.
5. The  device  has  a  tag  indicating  all  necessary  technical  data  and  other 

useful information about the device.
6. Use the device only as designated by this manual.
7. Prior to installation of the portable air conditioner, not connecting it to the 

mains, check and make sure that the mains socket for the air conditioner has 

a grounding pin and is properly grounded.
8. In case there is no grounding pin in your mains, operation of the portable 

air conditioner is life-threatening.

Dear Customer!

Thank you for a shrewd choice and purchase of Timberk portable electric air 
conditioner.
It will serve you for a long time.

9. Do not use adapters and extension cords to connect your portable air 

conditioner.
10. Improper installation and use of this air conditioner may lead to severe 

injuries or damage to your property.
11. Any maintenance must be performed by a specialized company and 

qualified specialists.

2. PRECAUTIONS

1. Do not block vents!
2. Make sure the inlet and outlet vent is not blocked.
3. Do not insert foreign objects into the air diffuser of the air conditioner. 

It is very dangerous since the fan rotates at high speed.
4. Install the device only on a horizontal surface to prevent condensed 

water leakage.
5. Do not install the floor-mounted air conditioner in the following places:
- in places exposed to direct sunlight;
- in the vicinity of open fire sources;
- in the vicinity of other operating heating devices;
- in places where water or steam splashes can contact the device;
- in rooms with increased humidity;
- close to swimming pools, bathrooms and shower rooms.
6. Do not use the device in an explosive or corrosive environment. Do not 

store gasoline and other volatile flammable liquids near the air 

conditioner   it is very dangerous!
7. Use the device to cool down air at ambient temperature 17-32°C. To use 

the device as a heater the room temperature must be 5-23°C.
8. Regularly clean filters to ensure efficient operation of the device.
9. To ensure reliable operation of the compressor, do not tilt the air 

conditioner.
10. If the device is disconnected, restarting must be performed not 

sooner than in 3.5 minutes to prevent the compressor failure.
11. At least 10 A current is required for the compressor to operate. To 

avoid overheating and fire risk, as well as damage to the inner electrical 

circuit, do not connect the device through extension cords.
12. The device is designed to cool, heat and dry air only in residential 

conditions and cannot be used for industrial purposes.
13. To avoid electric shock, a damaged power cord must be replaced only 

by an authorized service center and qualified specialists.
14. Prior to disposal of the device, it is necessary to remove batteries from 

it, after that they can be safely disposed.

2
2
3
4
5
6
7
8
8
9
9

23

www.timberk.com

   

 

 

 

 

 

 (  

 

)

Summary of Contents for AC TIM 12H P5BU

Page 1: ...e revised without any special advance notices 17 18 17 18 Models AC TIM 12H P5BU AC TIM 12H P5R AC TIM 14H P5 AC TIM 14H P5R www timberk com Electric floor air conditioner portable type single case El...

Page 2: ...be performed by a specialized company and qualifiedspecialists 2 PRECAUTIONS 1 Do not block vents 2 Make sure the inlet and outlet vent is not blocked 3 Do not insert foreign objects into the air dif...

Page 3: ...nology as well as change its technical characteristics to improve its consumer and technical properties without prior notice Model AC TIM 12H P5BU AC TIM 12H P5R AC TIM 14H P5 AC TIM 14H P5R Capacity...

Page 4: ...t the air outlethose theninsertitinthehole 2 Rotatetheairoutlethoseinthedirection indicatedbyarrow1andtakeit outfromtheremovablegrill 3 Rotate the air outlet hose in the direction indicated by arrow 2...

Page 5: ...e Press the timer button when the unit is not operating to set the desired time buttons3and4 Theunitwillbeautomaticallyswitchedonwhenthesettimeexpires Press POWER button before the set time expires Ti...

Page 6: ...eunitwillbeautomaticallyswitchedoff 3 Press ON OFF button before the set time expires Time setting will be canceledandtheunitwillbeswitchedoff 6 Automaticfanspeedbutton automaticventilationmode 7 High...

Page 7: ...trical components do not pour water on the air conditioner from a tap or a hose not included 3 Do not use the air conditioner if the power cord is damaged On the subject of replacing a damaged power c...

Page 8: ...inthesocketsecurelytoavoidoverheatingandriskoffire Donotpullthepowercordwithexcessiveforce itmaydamageit notincluded IMPORTANT At high humidity additional condensate removal will be required E4 symbol...

Page 9: ...1 Short circuit on a temperature sensor or a processor board Contact an authorized service center E2 Short circuit between a copper pipe of the temperature sensor and the processor board wiring Contac...

Page 10: ...4 5 5 6 7 6 8 7 9 8 9 9 9 10 10 11 11 6 7 8 9 10 11 1 2 3 4 5 6 15 3 4 ON OFF 4 SLEEP 1 SLEEP 2 1 2 SLEEP 2 2 3 4 3 3 5 9 E4 1 FUNC SET 2 TEMP 1 1 3 POWER 4 SLEEP 1 SLEEP 2 1 2 SLEEP 2 2 3 4 5 1 2 3 O...

Page 11: ...11 7 0 17 32 0 5 23 8 9 10 3 5 11 10 12 13 14 15 1 2 1 50 1 2 2 3 DF 14 7 7 1 POWER 2 SET 3 TEMP 1 30 1 25 4 TEMP 1 17 1 15 5 LCD 7 3 4 POWER 1 8 2 3 4 6 7 5 6 SPEED www timberk com www timberk com...

Page 12: ...X0 27 5 30 477x330x630 507x360x660 12000 3 5 12000 3 5 1480 1300 220 230 50 6 7 5 9 400 55 55 R410A B B I IPX0 27 5 30 477x330x630 507x360x660 14000 4 0 14000 4 0 1700 1500 220 230 50 7 7 6 8 450 70 5...