www.timberk.com • Electric air conditioner
7
3.TEMP up button. In the cooling mode each press of this button
raises the set temperature by 1°C up to maximum 30°C. In the heating
mode each press of this button raises the set temperature by 1°C up to
maximum 25°C.
4. TEMP down button. In the cooling mode each press of this button
lowers the set temperature by 1°C up to minimum 17°C. In the heating
mode each press of this button lowers the set temperature by 1°C up
to minimum 15°C.
5. LED display. The display shows the set temperature or the timer.
After the temperature and time are set the display returns to indicating
the current temperature.
6. FAN speed button. Press this button to select low [ ], medium
[ ],high [ ] or automatic [ ] fan speed button. When the automatic
speed is selected (in the cooling mode), high, medium or low speeds
are selected automatically depending on the difference between the set
temperature and the room temperature.
NOTICE:
You should not set the fan speed in the heating
or dehumidification mode since heating is
performed at high fan speed and dehumidification
is performed at low fan speed.
7. Programmable timer on/off button.
ON timer. The ON timer is used to automatically switch on the unit
upon expiration of the set time.
Press the timer button when the unit is not operating to set the
desired time (buttons 3 and 4).
The unit will be automatically switched on when the set time expires.
Press POWER button before the set time expires. Time setting will
be canceled and the unit will be switched on.
OFF timer. The OFF timer is used to automatically switch off the unit
upon expiration of the set time.
Press the timer button when the unit is operating to set the desired
time (buttons 3 and 4).
The unit will be automatically switched off when the set time expires.
Press ON/OFF button before the set time expires. Time setting will
be canceled and the unit will be switched off.
8. SLEEP button: after pressing this button the fan sets to low
speed.
(1) Press SLEEP button, set the sleep mode. Press the button again
to cancel the sleep mode.
(2) In the cooling mode one hour after the sleep mode is set the
temperature automatically increases by 1°C. In two hours the
temperature will increase by 2°C and the established mode is
maintained for the rest of the time. In the heating mode when SLEEP
function is activated the temperature is, on the contrary, decreased
by 2°C in 2 hours.
(3) When power supply is turned off, the sleep mode is automatically
switched off.
(4) When the unit is turned off, settings of the sleep mode are
automatically turned off.
The portable air conditioner is equipped with a protective circuit
featuring a 3 minute compressor activation delay. It means that it
takes 3.5 minutes for the compressor to activate after the unit is
switched on or dehumidification mode is switched to any other
mode.
9. Signaling.
“E4” signal is shown on the display at the maximum water level. To
resume operation, remove the rubber plug of the drainage hose at
the device's base to drain water at first. After water is drained, start
the unit. It will go to the normal operating mode.
Indicators for operating mode:
- cooling mode indicator
- heating mode indicator
- dry mode indicator
- sleep mode indicator
- operation indicator
NOTE:
While pressing and holding the keys up and down
switches to temperature readings in F (Fahrenheit)
or C (Celsius) and back.