2
208 VAC 3 Ph
30 Amps
240 VAC 3 Ph
30 Amps
460 VAC 3 Ph
20 Amps
480 VAC 3 Ph
20 Amps
Installation Requirements
Minimum Air Pressure
80 psi (550 kPa)
Maximum Air Pressure
100 psi (690 kPa)
Minimum Flow
6 cfm (170 Lpm)
Mouth Diameter
4 in (102mm)
Minimum Air Flow
600 cfm (17 kLpm)
Power
Grounding
Dust Extraction
Air Supply
The TigerSaw Miter must be powered by a dedicated circuit.
Voltages must be balanced between phases, as well as from
each phase to ground.
Line-to-line voltage must not exceed 250V for a 208/240V
saw system.
Line-to-line voltage must not exceed 500V for a 460/480V saw system.
•
DO NOT power a TigerStop positioning system directly with a delta high-leg transformer. If delta high-leg power must
be used to power a TigerSaw Miter, then the isolation transformer between incoming power and the positioner MUST
NOT receive the high leg.
The TigerSaw Miter must be properly grounded.
TigerStop recommends a qualified electrician perform the grounding of the system.
Warning: Operating machinery without proper grounding can result in shock or electrocution.
There are two dust extraction ports, one on top of the saw and another in the base.
Effective dust extraction is critical to the longevity of the TigerSaw Miter.