50
To adjust sensitivity...
1. Ensure there is no material under the sensor
Note: The IR sensor will make a small red dot on the table.
2. Adjust the dial so that the yellow light is off.
3. Slide a sample piece of material under the IR sensor.
4. Adjust the dial so that the yellow light comes on when it sees the edge of the material.
5. Slide the entire length of the material under the IR sensor and ensure the yellow light is constantly
on until it reaches the end edge of the material.
Pusher Foot Height Adjustment
The pusher foot will raise and lower as it processes material. The travel of the foot can be adjusted
by adjusting the position of the cylinder that moves the foot.
To adjust pusher foot height...
1. Loosen the bolts that hold the pusher foot cylinder bracket to the base.
2. Slide the bracket to the desired position.
3. Tighten the bolts.
Kill Line Tension Adjustment
The red kill line must be under tension to be reset. Adjust the bolt at the end of the table.
To adjust kill line tension...
1. Look at the kill line switch. It has a black indicator that is located near a green strip.
2. Adjust the tensioning bolt at the end of the kill line bracket.
3. The black indicator on the switch should be in the middle of the green strip.