tigerlight SL160 Installation Instruction Download Page 1

Drawings herein for SL160 are used as examples.

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION

IMPORTANT INSTALLATION INFORMATION
1.

Normal operating environment and temperature: -40

℃-+

50

℃. 

   Fixtures is suitable for Airport, Car Dealerships, Ac hitectural, 
   Factory, Warehouse, High Mast lighting and stadium lighting.

2.

Before commencing installation or maintenance, ensure electricity 

   is switc hed off at the mains. Installation or maintenance should be 
   carried out by a qualified electrician.

3.

The luminaire must not, under any circumstances, be installed 

   directly to flammable materials, and luminaires must not be 
   covered with any flammable materials.

4.

Mounting height range of 6 to 12 meters, this model is suitable 

   for outdoor lighting.

5.

Ensure there is adequate free air circulation of at least 50cm 

   around the luminaire. All luminaires run hot. It is the installer's 
   responsibility to consider fire risk and take appropriate precautions.

Installation Instruction & Installation Steps

1

2

3

4

STEP 1:

Use a 6mm hex wrenc h to loosen the screws that secure the lamp 
post above the lamp arm, then slide fixture on to pole through 
opening on the rear of housing. See Figure 1.

STEP 2:

Ensure to slide fixture to the inner end of tenon, then tighten 
locking bolts with 5mm hex wrenc h or its equivalent to ensure the 
fixture is fixed to polefirmly.
See Figure 2.

STEP 3:

1.Loosen hinged hatc h locking bolts with 5mm hex wrenc h or its 
   equivalent, and open the hatc h for led driver compartment access.
2.Get mains power supply cord into led driver compartment via 
   cable gland, Install power connections as per Figure 6, and lock 
   the gland to mains power supply cord tightly.

STEP 4:

1.Referring to Fig. 4, use a wrenc h loosen Screw by 3-5 threads to 
   adjust the fixtures angle. Once angle is decided, secure the hex 
   screw with 25 n.m of force.
2.Using the in-built bubble level, align fixture to the horizontal plane. 
   Adjust screws accordingly. Once leveled use 45 n.m to secure the 
   fixture to the light pol e . Ensure that the fixture is now attac hed to 
   the light pole securely. Close the cover and secure the cover screws 
   with 25 n.m of force.

W

H

L

Locking bolts

Pole

Hinged hatc h
locking bolts

Cover

Mains power
supply cord

Cable gland

Screws to adjust and lock rotatable tenon

415V High Voltage LED Street Light

INSTALLATION INSTRUCTION

LED Street Light

INSTALLATION INSTRUCTION

Reviews: